2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia) 2017
DOI: 10.1109/ifeec.2017.7992190
|View full text |Cite
|
Sign up to set email alerts
|

Control strategy of single-phase 3LNPC-CR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…It was well developed during the 1990s and attracted more interest after 1997 [19], [20]. During the past decades, scholars and engineers have carried out many meaningful studies about CHBI which can be concluded as the following three aspects: 1) improving the harmonic performance [21][22][23]; 2) solving the computational burden to improve the dynamic response [24][25][26]; 3) balancing the DC voltage and developing fault-tolerant control (detection, isolation and reconfiguration) to improve system reliability, maintainability and survivability [27][28][29][30][31][32][33][34][35][36]. Especially for the third aspect, the hardware redundancy and software redundancy [37] are the two efficient and main stream solutions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It was well developed during the 1990s and attracted more interest after 1997 [19], [20]. During the past decades, scholars and engineers have carried out many meaningful studies about CHBI which can be concluded as the following three aspects: 1) improving the harmonic performance [21][22][23]; 2) solving the computational burden to improve the dynamic response [24][25][26]; 3) balancing the DC voltage and developing fault-tolerant control (detection, isolation and reconfiguration) to improve system reliability, maintainability and survivability [27][28][29][30][31][32][33][34][35][36]. Especially for the third aspect, the hardware redundancy and software redundancy [37] are the two efficient and main stream solutions.…”
Section: Introductionmentioning
confidence: 99%
“…However, the method is not suitable for CHBC due to its special structure. In [30], a modified control strategy based on a CHB rectifier is proposed to solve the unbalanced DC voltage. The cost function and mathematical model are established in the control strategy.…”
Section: Introductionmentioning
confidence: 99%