Controlled Closing of PT Delta Winding for Identifying Faulted Lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 5 publications
0
18
0
Order By: Relevance
“…Equations (14) and (15) are used as the criteria to distinguish between the faulted and healthy feeders. The process of faulted feeder identification begins with the injection of proper current by the active grounding system to limit the fault current to provide the service continuity.…”
Section: Faulted Feeder Identification Algorithmmentioning
confidence: 99%
See 2 more Smart Citations
“…Equations (14) and (15) are used as the criteria to distinguish between the faulted and healthy feeders. The process of faulted feeder identification begins with the injection of proper current by the active grounding system to limit the fault current to provide the service continuity.…”
Section: Faulted Feeder Identification Algorithmmentioning
confidence: 99%
“…Generally, the identification of the location of a ground fault has become a challenge in the presence of unbalanced loads connected to the laterals, which is complicated by feeders [30]. From 7, (14) and (15), it can be realised that variations of zero sequence current in the healthy and faulted feeders are a function of fault location. This is due to the fact that the fault location determines the series impedance between the main bus and the fault point.…”
Section: Effects Of Fault Location On the Proposed Algorithmmentioning
confidence: 99%
See 1 more Smart Citation
“…This added fundamental current component has been also exploited to find the fault distance. In the same scenario of providing zero sequence current loops toward identifying the faulty feeder, a Earth Fault Distance Estimation Using Active Traveling Waves in Energized Compensated MV Networks Nagy I. Elkalashy, Nehmdoh A. Sabiha and Matti Lehtonen T short period of switching concept is addressed in [16]- [17]. In [16], the neutral is earthed using a controlled-thyristor.…”
Section: Introductionmentioning
confidence: 99%
“…This provides transient currents in the earth loop for a short period exploited to identify the faulty feeder. In [17], the idea of injecting pulses has been implemented using opendelta/earthed-star transformer. A thyristor has been triggered to close the open-delta windings.…”
Section: Introductionmentioning
confidence: 99%