2018
DOI: 10.1002/macp.201800173
|View full text |Cite
|
Sign up to set email alerts
|

Convenient Graphical Visualization of Messages Encoded in Sequence‐Defined Synthetic Polymers Using Kendrick Mass Defect Analysis of their MS/MS Data

Abstract: Kendrick mass defect (KMD) analysis is shown here to be a convenient method to read binary messages encoded in the structure of two types of sequence‐defined synthetic polymers, namely, polyurethanes and poly(alkoxyamine phosphodiester)s. KMD analysis allows graphical ranking of mass data obtained for species containing repeating units. This is performed on MS/MS data in which distribution of fragments reveals the comonomer sequence of digital macromolecules. Choosing one coding monomer as the base unit, KMD c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…Kendrick mass defect (KMD) analysis has been used as a convenient tool to visualize the binary code embedded in sequence-defined polymers. 29 Such data treatment typically presupposes that MS 2 spectra measured at high mass resolution and high mass accuracy are available. In this study, a remainder of Kendrick mass (RKM) analysis was employed due to the lower mass accuracies encountered upon MALDI-MS 2 of ions with high m/z ratio.…”
Section: Calculation Of Remainder Of Kendrick Massmentioning
confidence: 99%
“…Kendrick mass defect (KMD) analysis has been used as a convenient tool to visualize the binary code embedded in sequence-defined polymers. 29 Such data treatment typically presupposes that MS 2 spectra measured at high mass resolution and high mass accuracy are available. In this study, a remainder of Kendrick mass (RKM) analysis was employed due to the lower mass accuracies encountered upon MALDI-MS 2 of ions with high m/z ratio.…”
Section: Calculation Of Remainder Of Kendrick Massmentioning
confidence: 99%
“…Homologous ions form a polymeric distribution and thus line up horizontally in a KMD plot displaying KMDs versus m / z while different distributions are displayed as parallel lines . This is an elegant data processing and visualization tool used to filter background peaks in congested mass spectra, or instantly sort polymer ion series by their repeat units, end‐groups, adducted ions and charge states among other features . A regular KMD analysis depends on R only and produces a single plot often displaying clustered clouds of points along a limited part of the y ‐axis.…”
Section: List Of Parameters Variables and Mathematical Functionsmentioning
confidence: 99%
“…The resolution‐enhanced KMD plot is thus a dynamic graph suitable for mass measurements of ultrahigh to medium accuracy . Positive natural divisors X ∈ ℤ + within a “recommended range” round()230.25emRXround()2R have been proposed earlier for ease of practical use . However, the use of positive real numbers has been suggested to increase the number of divisors denoted x ∈ ℝ + and hypothetically achieve a “continuous” enhancement of resolution as discussed hereafter.…”
Section: List Of Parameters Variables and Mathematical Functionsmentioning
confidence: 99%
“…As a result, coded sequences could be literally read from peak-to-peak distance in MS/MS spectra and a simple algorithm was created for automated extraction of digital data [15]. Alternatively, the code could be graphically read using Kendrick mass defect plots [16]. Although optimal for straightforward MS/MS decoding in the negative ion mode, sequence-defined PUs exhibited decreasing ionization yield as their chain length increased.…”
Section: Introductionmentioning
confidence: 99%