2013
DOI: 10.1364/ao.52.002125
|View full text |Cite
|
Sign up to set email alerts
|

Cooled infrared filters and dichroics for the sea and land surface temperature radiometer

Abstract: The sea and land surface temperature radiometer (SLSTR) is a nine-channel visible and infrared high-precision radiometer designed to provide climate data of global sea and land surface temperatures. The SLSTR payload is destined to fly on the Ocean and Medium-Resolution Land Mission for the ESA/EU global monitoring for environment and security (GMES) programme Sentinel-3 mission to measure the sea and land temperature and topography for near real-time environmental and atmospheric climate monitoring of the Ear… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…To acquire the embedded thermo-optical data properties for thin film simulations, we characterized and correlated the thermal behavior from a historic repository [14][15][16] of PbTe/ZnSe narrow bandpass filters, manufactured over a course of two decades, and covering a wide range of wavelengths, bandwidths, and multilayer design types. These filters were manufactured by thermal evaporation using a modified Balzers BA510 deposition chamber.…”
Section: Experimental Data and Simulation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To acquire the embedded thermo-optical data properties for thin film simulations, we characterized and correlated the thermal behavior from a historic repository [14][15][16] of PbTe/ZnSe narrow bandpass filters, manufactured over a course of two decades, and covering a wide range of wavelengths, bandwidths, and multilayer design types. These filters were manufactured by thermal evaporation using a modified Balzers BA510 deposition chamber.…”
Section: Experimental Data and Simulation Methodsmentioning
confidence: 99%
“…The selection of bandpass filters used in this study were deposited with substrate temperatures between 185-210 °C. Further deposition details are discussed in the papers where the filters were first published [14][15][16]. The filters were all newly characterized by extraction from high temperature FTIR spectral measurements across the range of 20-200 ºC, where the observed wavelength displacements were correlated with multilayer design properties in [5].…”
Section: Experimental Data and Simulation Methodsmentioning
confidence: 99%
“…Two blackbody sources, that are viewed by the scanners every 600 ms, provide continuous calibration of the infrared channels, and a diffuser based Visible Calibration system (VISCAL) for calibrating the solar reflectance bands. A more detailed description of the SLSTR design and the predicted performance is described in [7][8][9]. The SLSTR instruments developed for ESA-ESTEC by an industrial consortium led by Leonardo Company (Firenze, Italy) involving Jena Optronik (Jena, Germany) and RAL Space (Harwell Oxford, UK).…”
Section: Introductionmentioning
confidence: 99%
“…This motivated this work to design and develop a rover with a radiation detector. smooth variable structure filter has also been extensively reviewed for its potential in nonlinear control and estimation in robotics [40,[43][44][45][46][47][48][49][50]. Additionally, the use of Kalman filter and its variants in robotic manipulators has shown promising results [51][52][53][54][55][56][57][58][59][60][61][62][63][64][65][66][67][68][69].…”
Section: Motivationmentioning
confidence: 99%