2014
DOI: 10.5755/j01.eee.20.10.4989
|View full text |Cite
|
Sign up to set email alerts
|

Coreless, Contactless Power Supply System with DSP Controlled Active Compensation of Parameter Changes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Table IV shows that there are 27 representative experiments totally; Except for the experiment number n, the "1", "2"and "3" represent "level 1", "level 2" and "level 3" of each factor as listed in Table III; The order of factors is determined by referring to [16] ("×" is the notation of interaction). The index of the calculated "k Q " is listed in the Table IV for each representative experiment by substituting AC resistance and mutual inductance of the windings obtained by FEM simulations into (4).…”
Section: Orthogonal Experiments Designmentioning
confidence: 99%
“…Table IV shows that there are 27 representative experiments totally; Except for the experiment number n, the "1", "2"and "3" represent "level 1", "level 2" and "level 3" of each factor as listed in Table III; The order of factors is determined by referring to [16] ("×" is the notation of interaction). The index of the calculated "k Q " is listed in the Table IV for each representative experiment by substituting AC resistance and mutual inductance of the windings obtained by FEM simulations into (4).…”
Section: Orthogonal Experiments Designmentioning
confidence: 99%
“…On the primary side an additional compensator must be synchronized with the voltage V r on the C r1 capacitor. Detailed description and proposed control procedure of such a compensator was previously presented in [18,19].…”
Section: Proposed Icet System Constructionmentioning
confidence: 99%
“…Investigations were performed for two cases: with an active compensation circuit and without it. To conduct simulations and experiments previously presented topology and control the strategy [18,19] of the compensator were used.…”
Section: Introductionmentioning
confidence: 99%
“…Developments in the field of semiconductor technology allow ultra—compact and high efficiency energy conversion and conditioning . Industrial drives and electromobility [4,8] open new areas of wide power electronics use. Emerging fields also include plasma systems , renewable energy sources, components, and converters for the flexible alternating current transmission systems—FACTS.…”
Section: Introductionmentioning
confidence: 99%