Coronary balloon angioplasty through diagnostic 6 french catheters

Abstract: We investigated the use of ultralow profile balloon catheters (Scimed ACE, USCI Probe, Cordis, Orion) for coronary angioplasty through 6 French diagnostic catheters (Schneider, Cordis). Contrast injection was assisted with a Hercules pump (Cordis) in all cases. During 21 procedures, angioplasty of 27 lesions in 20 selected patients was attempted (1.3 lesion/procedure). Twelve lesions were in the right, 10 in the left anterior descending, and 5 in the left circumflex coronary artery. Balloon size varied between… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

1992
1992
2006
2006

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…Noncompliance of the patient regarding strict bedrest after the procedure (at a 30 degree angle for 8 hr) has been reported to be a substantial factor for femoral complications after PTCA, increasing the risk of hematoma formation by a factor of 14 and the risk of rebleeding by a factor of 2.5 [12,16]. Reducing the sheath size and/or the revival of the transradial approach was presumed to result in fewer vascular complications and increased patient comfort after PTCA [17][18][19][20][21][22][23][24][25]; however, bleeding complications were not related to the sheath sizes [13,26,27].…”
Section: Discussionmentioning
confidence: 98%
“…Noncompliance of the patient regarding strict bedrest after the procedure (at a 30 degree angle for 8 hr) has been reported to be a substantial factor for femoral complications after PTCA, increasing the risk of hematoma formation by a factor of 14 and the risk of rebleeding by a factor of 2.5 [12,16]. Reducing the sheath size and/or the revival of the transradial approach was presumed to result in fewer vascular complications and increased patient comfort after PTCA [17][18][19][20][21][22][23][24][25]; however, bleeding complications were not related to the sheath sizes [13,26,27].…”
Section: Discussionmentioning
confidence: 98%
“…However, advances in equipment, including reductions in device and catheter caliber, have allowed for coronary angioplasty procedures to be performed through 4-6 Fr catheters and sheaths [37][38][39][40]. Several retrospective studies have identified associations between sheath size and access site complications [5,7,8], although other studies have not found any association [6,10].…”
Section: Bleeding Complications With Early Invasive Strategymentioning
confidence: 97%
“…Even the atrial repolarization (small arrow) can be discerned in the lntracoronary lead. withdrawal through the first generation of 6F catheters used for PTCA [3]. With the new generation ACE balloons featuring a slippery coating, retrieving the balloon through 6F catheters with a lumen of 0.050 inch or larger has been possible in 90% of cases with balloon sizes up to 4.0 mm.…”
Section: Winging Of the Balloon Frequently Prevented Balloonmentioning
confidence: 99%