The start of an increase in P wave size does not correspond with the entrance of the right atrium. The anatomic equivalent for the electrophysiological changes of the ECG is the pericardial reflection. ECG guidance is unable to distinguish between venous and arterial catheter position.
We investigated the use of ultralow profile balloon catheters (Scimed ACE, USCI Probe, Cordis, Orion) for coronary angioplasty through 6 French diagnostic catheters (Schneider, Cordis). Contrast injection was assisted with a Hercules pump (Cordis) in all cases. During 21 procedures, angioplasty of 27 lesions in 20 selected patients was attempted (1.3 lesion/procedure). Twelve lesions were in the right, 10 in the left anterior descending, and 5 in the left circumflex coronary artery. Balloon size varied between 2.5 and 3.5 mm. Twenty lesions could be successfully dilated (74%) through the 6 French catheter and 7 lesions required an exchange to a 7 French angioplasty guiding catheter. For 5 cases, another balloon was also necessary to complete the procedure. The final overall success rate was 100% per patient and per lesion and there were no major complications. Despite the small internal catheter lumen (1.22 mm) coronary visualization was adequate, and mechanical support was good. Failures of 6 French catheters were attributed to insufficient torque control and excessive friction when the balloon crossed the tapered end of the diagnostic catheter. Coronary angioplasty through a diagnostic 6 French catheter is feasible and may represent a reasonable alternative for simple cases that are done during the same session as the diagnostic angiography. Once available, 6 French high flow angioplasty guiding catheters without a tapered tip should improve success while retaining the advantage of a small femoral puncture site.
While attempting to dilate a distal lesion in a right coronary artery, using a balloon-on-a-wire catheter, circumferential balloon rupture occurred with temporary entrapment of the balloon in the stenosis. The balloon was retrieved, and the dilatation completed, using an over-the-wire balloon catheter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.