“…Charge-transfer resistance and double-layer capacitance are related to non-cohesion of active mass of electrodes; contacting resistances represent the existence of stratification and corrosion of electrodes; nonlinear diffusion impedances characterize sulfating of electrodes [4,9]. Multi-scale SoC/SoH judgment based on EIS is an extension of threshold-based management [10,11]; circuits elements are nonlinearly influenced by various factors, e.g., SoC, charging or discharging, superimposed DC current [12]; other form signals, such as short step response, can take place of sinusoidal excitation to demonstrate dominant aging mechanisms on battery capacity [8]. The leading edge of BMS to forecast and optimize batteries' SoC/SoH is usually based on time domain simulation [13,14]; therefore, extracting directional DC charge-transfer resistances from an AC Nyquist curve is significant in time domain research on BMS.…”