2020
DOI: 10.1016/j.ejrad.2020.108875
|View full text |Cite
|
Sign up to set email alerts
|

Correlation between optic nerve sheath diameter measured on imaging with acute pathologies found on computed tomography of trauma patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 39 publications
0
13
0
2
Order By: Relevance
“…The difference between minutes 0 and 120 it has been shown to be consistent with measurements made by US 10 . The elevation of ONSD due to the increase of ICP in patients with TBI was shown in several studies 11,12,13,14 . Although the importance of urgent intervention for ICP increase, there is no method developed for ICP monitoring in the emergency clinic including the acute trauma period.…”
Section: Gcs Minute 0 Minute 60 Minute 120mentioning
confidence: 84%
See 1 more Smart Citation
“…The difference between minutes 0 and 120 it has been shown to be consistent with measurements made by US 10 . The elevation of ONSD due to the increase of ICP in patients with TBI was shown in several studies 11,12,13,14 . Although the importance of urgent intervention for ICP increase, there is no method developed for ICP monitoring in the emergency clinic including the acute trauma period.…”
Section: Gcs Minute 0 Minute 60 Minute 120mentioning
confidence: 84%
“…It has been specified that the optic nerve sheath diameter (ONSD) increases along with the increase of ICP due to the extension of the dura mater surrounding the optic nerve, and the most adequate measurement site is 3 mm distant from the distal side of the ocular globe 6,7 . Several studies were conducted through brain tomography (CT), magnetic resonance imaging, and ultrasound (US) and consistent results were obtained 9,10,11,12 . A meta-analysis stated that ONSD thickness wider than 5 mm measured by US is an indicator for the increase in ICP, and sensitivity and specificity of such measurement are 99 and 77%, respectively 13 .…”
Section: Introductionmentioning
confidence: 80%
“…5,9 Dilatasi selubung nervus optikus dapat dinilai secara tidak langsung dari pencitraan CT-scan kepala, MRI, atau ultrasonografi. 1,9,10 CT-scan kepala, dikombinasikan dengan gejala dan tanda klinis, dapat menjadi petunjuk awal diagnosis dan penentuan penatalaksanaan selanjutnya. CT-scan juga dapat melihat abnormalitas otak lain seperti kelainan bentuk sisterna dan ventrikel, midline shift, hematoma, dan diferensiasi substansia grissea/alba.…”
Section: Pendahuluanunclassified
“…There are studies reporting that computed tomography (CT), magnetic resonance imaging and ultrasonography (USG) can also be used for this purpose. [11][12][13][14] The ONSD diameter has been reported to increase if there is an increase in the ICP since the dura mater extends to surround the optic nerve, and the most suitable area for the measurement has been reported to be 3 mm behind the globe in particular. [7,9] Pediatric Glasgow Coma Score (pGCS) is a significant scoring system that can be used in the follow-up of patients with TBI and can guide the clinician.…”
Section: Introductionmentioning
confidence: 99%
“…According to the current data, ICP monitoring is important in the management of treatment in cases with a pGCS of 8 or less. [5,8,12] We aimed to investigate the correlation between the ONSD change on brain CT used in the follow-up of pediatric patients with TBI and pGCS and the usability of ONSD, an indicator of ICP, in the follow-up of patients.…”
Section: Introductionmentioning
confidence: 99%