Correlation of μXRF and LA-ICP-MS in the analysis of a human bone-cartilage sample

Abstract: Determining the local distribution of major, minor and trace elements in biological tissues provides fundamental information on the chemical composition and often allows conclusions on the underlying biochemical mechanisms. Within...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 37 publications
0
4
0
Order By: Relevance
“…Deliver ablated particles to the ICP‒MS instrument’s secondary excitation source for digestion and ionization. then analyze the plasma torch’s excited ions by mass spectrometry 25 μm Quantitative measurement that detects elements spatially Relatively low accuracy and spatial resolution Ca, P, S, Zn, Na, Mg, K 106 , 181 Reflects the spatial expression of elemental distribution in the OA tissue SR-μXRF Utilizing synchrotron radiation as an excitation source. An inner shell electron of the atom is struck and ejected by an X-ray.…”
Section: Different Scales and Different Techniques For Deep Spatial P...mentioning
confidence: 99%
“…Deliver ablated particles to the ICP‒MS instrument’s secondary excitation source for digestion and ionization. then analyze the plasma torch’s excited ions by mass spectrometry 25 μm Quantitative measurement that detects elements spatially Relatively low accuracy and spatial resolution Ca, P, S, Zn, Na, Mg, K 106 , 181 Reflects the spatial expression of elemental distribution in the OA tissue SR-μXRF Utilizing synchrotron radiation as an excitation source. An inner shell electron of the atom is struck and ejected by an X-ray.…”
Section: Different Scales and Different Techniques For Deep Spatial P...mentioning
confidence: 99%
“…Turyanskaya and co-workers 165,166 focussed on the analysis of bone by LA-ICP-MS and X-ray techniques for different purposes in two papers. In the rst, 165 a human bone-cartilage sample was used to directly compare LA-ICP-MS and mXRF spectrometry.…”
Section: Imaging With Ms X-rays and Libsmentioning
confidence: 99%
“…Turyanskaya and co-workers 165,166 focussed on the analysis of bone by LA-ICP-MS and X-ray techniques for different purposes in two papers. In the rst, 165 a human bone-cartilage sample was used to directly compare LA-ICP-MS and mXRF spectrometry. Quantitative results were obtained for both techniques using the CRM IAEA H-5 (animal bone) and an in-house prepared cartilage standard.…”
Section: Imaging With Ms X-rays and Libsmentioning
confidence: 99%
“…18 Matrix-matched synthetic hydroxyapatite materials doped with analyte metals were developed to improve quantication of calcied tissues. 15,[19][20][21] However, issues arose from being unable to obtain matched ablation behaviour between the calibration material and the sample, 15 with neither ablation yield or normalised sensitivity reported. Previous hydroxyapatite standards suffered from elemental inhomogeneity with relative standard deviation (RSD) up to 32% due to grain size and poor uptake into the crystal lattice.…”
Section: Introductionmentioning
confidence: 99%