2022
DOI: 10.1016/j.corsci.2022.110238
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion behaviour of biomedical Ti under simulated inflammation: Exploring the relevance of grain refinement and crystallographic texture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 75 publications
2
15
0
Order By: Relevance
“…The composition and structure of the oxide films formed on the studied alloys after the PP test in the PBS solution were analyzed by the XPS technique. Ti 2p spectra in Figure indicate that the oxide layer formed on all the studied alloys sequentially consisted of TiO 2 , Ti 2 O 3 , and TiO . Notably, only TiO 2 was detected for the Ti6Al4V-5Cu UG alloy when the sputtering time increased to 30 s, while the obvious stoichiometry (Ti 2 O 3 and TiO) emerged beneath the outer TiO 2 layers on Ti6Al4V CG and Ti6Al4V-5Cu CG alloys.…”
Section: Resultsmentioning
confidence: 91%
See 1 more Smart Citation
“…The composition and structure of the oxide films formed on the studied alloys after the PP test in the PBS solution were analyzed by the XPS technique. Ti 2p spectra in Figure indicate that the oxide layer formed on all the studied alloys sequentially consisted of TiO 2 , Ti 2 O 3 , and TiO . Notably, only TiO 2 was detected for the Ti6Al4V-5Cu UG alloy when the sputtering time increased to 30 s, while the obvious stoichiometry (Ti 2 O 3 and TiO) emerged beneath the outer TiO 2 layers on Ti6Al4V CG and Ti6Al4V-5Cu CG alloys.…”
Section: Resultsmentioning
confidence: 91%
“…Ti 2p spectra in Figure 3 indicate that the oxide layer formed on all the studied alloys sequentially consisted of TiO 2 , Ti 2 O 3 , and TiO. 49 Notably, only TiO 2 was detected for the Ti6Al4V-5Cu UG alloy when the sputtering time increased to 30 s, while the obvious stoichiometry (Ti 2 O 3 and TiO) emerged beneath the outer TiO 2 layers on Ti6Al4V CG and Ti6Al4V-5Cu CG alloys. According to the Gibbs-free energy function diagram, 50 TiO 2 has the highest stability with the lowest standard free energy among all the titanium oxides.…”
Section: Xps Analysis Of the Passive Filmmentioning
confidence: 95%
“…6. In this circuit, R s is solution resistance, R f is resistance of passive film, and CPE is constant phase element representing the capacitance of passive film [47]. CPE element can be described using two parameters: Q and n,…”
Section: E / V(vs Sce) I / (A•cmmentioning
confidence: 99%
“…This improvement in corrosion resistance for TNTZ CRA with longer immersion times can be attributed to the presence of Nb and Ta in the alloy, both of which have higher valences than Ti. [47,48] According to literature, [47] the incorporation of Nb 5þ or Ta 5þ cations into the Ti oxide structure contributes to a decrease in the concentration of anion vacancies. These stoichiometric defects arise due to the presence of titanium suboxides, specifically those with lower titanium oxidation states such as Ti 3þ and Ti 2þ .…”
Section: Electrochemical Corrosionmentioning
confidence: 99%