2011
DOI: 10.4028/www.scientific.net/ssp.183.185
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion of Ni-Al and Ni-Al-Al<sub>2</sub>O<sub>3</sub> Flame Sprayed Coatings of „CastoDyn 8000" System in 0.01 M H<sub>2</sub>SO<sub>4</sub> and 3.5% NaCl Solutions

Abstract: In the paper researches results of corrosion properties of Ni-Al alloy and Ni-Al-Al2O3 composite coatings were presented. Coatings were obtained by flame spraying of "Casto-Dyn 8000" torch. During coatings flame spraying of torch was used a small distance from the substrate. Instead of commonly used spray distance 150 mm, 100 mm was used. The studies in 0.01 M H2SO4 and 3.5% NaCl (artificial seawater) environments were realized. Evaluated coatings are more corrosion resistant in the 3.5% NaCl environment than … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 8 publications
0
14
0
Order By: Relevance
“…Used in studies three electrode system consists of the following elements: the sample, an auxiliary electrode (polarizing) of titanium and platinum reference electrode (saturated calomel electrode) [11,12]. All electrodes were placed in a tank with 3.5% water solution of NaCl.…”
Section: Methodsmentioning
confidence: 99%
“…Used in studies three electrode system consists of the following elements: the sample, an auxiliary electrode (polarizing) of titanium and platinum reference electrode (saturated calomel electrode) [11,12]. All electrodes were placed in a tank with 3.5% water solution of NaCl.…”
Section: Methodsmentioning
confidence: 99%
“…Before the measurements the samples were exposed in the electrolyte to stabilize the corrosion potential. During measuring the electrolyte was continuously mixed using a magnetic stirrer [6][7][8][9]. The samples were degreased before the test.…”
Section: The Research Methodologymentioning
confidence: 99%
“…Currently, one of the best research methods of resistance to this type of corrosion is electrochemical impedance spectroscopy (EIS). It allows you to not only determine the electrochemical corrosion resistance but also gives the opportunity to evaluate homogeneity of the corrosion process on the metal surface [6,7,10].…”
Section: Introductionmentioning
confidence: 99%
“…Before the measurements, the samples were exposed in the electrolyte to stabilize the corrosion potential. During measuring, the electrolyte was continuously mixed using a magnetic stirrer [5,8,[10][11][12]. The samples were degreased before the test.…”
Section: Fig 2 Tri-flute Tool Used In Researchmentioning
confidence: 99%
“…Currently, one of the best research methods of resistance to this type of corrosion is electrochemical impedance spectroscopy (EIS). It allows not only determine the electrochemical ISSN: 1231-4005 e-ISSN: 2354-0133 ICID: 1132702 DOI: 10.5604/12314005.1132702 corrosion resistance but also gives the opportunity to evaluate homogeneity of the corrosion process on the metal surface [5,8,[10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%