2016
DOI: 10.1016/j.msec.2016.05.099
|View full text |Cite
|
Sign up to set email alerts
|

Covalent attachment of aptamer onto nanocomposite as a high performance electrochemical sensing platform: Fabrication of an ultra-sensitive ibuprofen electrochemical aptasensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(14 citation statements)
references
References 45 publications
1
13
0
Order By: Relevance
“…In aptasensors, redox probe is charged oppositely to aptamer so that electrostatic repulsion makes the interface very sensitive to the shielding of aptamer charge or its compensation dye to target interactions. Such impedimetric sensors were reported for determination of other low‐molecular analytes, e. g., patulin , ochratoxin A , kanamycin , ibuprofen etc. The use of conductive polymers like PANI or poly( p ‐phenylene diamine) increases sensitivity of the detection due to pH‐ or charge dependency of underlying layer.…”
Section: Resultsmentioning
confidence: 99%
“…In aptasensors, redox probe is charged oppositely to aptamer so that electrostatic repulsion makes the interface very sensitive to the shielding of aptamer charge or its compensation dye to target interactions. Such impedimetric sensors were reported for determination of other low‐molecular analytes, e. g., patulin , ochratoxin A , kanamycin , ibuprofen etc. The use of conductive polymers like PANI or poly( p ‐phenylene diamine) increases sensitivity of the detection due to pH‐ or charge dependency of underlying layer.…”
Section: Resultsmentioning
confidence: 99%
“…Still, in general, the most sensitive methods comprised biological entities for highly specific biorecognition. For instance, biosensors with immobilized antibodies (immunosensor) or DNA/RNA fragments (aptasensor) achieved considerably lower values of LOD, reaching concentrations between 10 −5 to 10 −8 μmol L −1 , either using graphene [ 86 , 90 ], or CNTs [ 116 , 118 ] as signal enhancer and substrate for biomolecules attachment. It is worth noting that only one work [ 126 ] resorted to enzymatic biorecognition of pharmaceuticals, which shows a clear gap since many pharmaceutical drugs have phenolic derivatives that can act as substrates of enzymes such as laccase, tyrosinase, or hydrogen peroxidase [ 152 ].…”
Section: Overall Comparison Between Reported Nanostructured Carbonmentioning
confidence: 99%
“…Tap water was analyzed as real sample with no traces of diclofenac being found [117]. It seems evident that the most sensitive (bio)sensors are based in highly specific recognition elements such as MIP [122,128] or biological entities involving aptamers [118] and antibodies [104,116,125]. In this way, the lowest LOD (6.2 × 10 −9 µmol L −1 ) corresponded to a MIP sensor developed for 17β-estradiol detection in environmental waters.…”
Section: Carbon Nanotubesmentioning
confidence: 99%
“…Several methods have already been reported for quantitative determination of KP, including liquid chromatography-mass spectrometry [ 3 ], UV-fluorescence [ 4 ], ion chromatography [ 5 ], flow injection with chemiluminescence [ 6 ], or electrochemical detection [ 7 ]. Both chromatographic and non-chromatographic techniques usually require rigorous sample preparation and expensive extraction methods (including solid-phase extraction) when real samples are considered.…”
Section: Introductionmentioning
confidence: 99%
“…A similar electrode was utilized by Ghoneim and Tawfik [ 10 ], and in a Britton-Robinson buffer (pH 2.0) the LOD was 0.10 ng mL –1 . Next, a setup containing glassy carbon (GC) electrode with multiwalled carbon nanotubes/ionic liquid/chitosan composite for covalent immobilization of the ibuprofen by specific aptamer was proposed [ 7 ].…”
Section: Introductionmentioning
confidence: 99%