Critical Response of Elastic-Plastic Structures to Near-Fault Ground Motions and Its Application to Base-Isolated Building Structures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 34 publications
1
2
0
Order By: Relevance
“…It was demonstrated that the plastic deformation amplitude in the base-isolation story can be evaluated by the proposed method with reasonable accuracy. It was found in the previous paper (Takewaki et al, 2017) that, when a 2DOF base-isolation building is transformed into an SDOF system and the closed-form solution for the critical elastic-plastic response of an SDOF system is applied to obtain the maximum deformation of the base-isolation story, it is necessary to choose a transformation method based on (i) the rigid super-structure approximation (low and middlerise buildings) and (ii) the ignorance of the base-isolation story mass and series-spring treatment (high-rise buildings), depending on the number of stories of buildings. In contrast, the proposed method using the 2DOF system does not need such selection of the transformation methods and it enables a unified evaluation of the maximum deformation in the base-isolated story regardless of the number of stories.…”
Section: Discussionsupporting
confidence: 53%
See 1 more Smart Citation
“…It was demonstrated that the plastic deformation amplitude in the base-isolation story can be evaluated by the proposed method with reasonable accuracy. It was found in the previous paper (Takewaki et al, 2017) that, when a 2DOF base-isolation building is transformed into an SDOF system and the closed-form solution for the critical elastic-plastic response of an SDOF system is applied to obtain the maximum deformation of the base-isolation story, it is necessary to choose a transformation method based on (i) the rigid super-structure approximation (low and middlerise buildings) and (ii) the ignorance of the base-isolation story mass and series-spring treatment (high-rise buildings), depending on the number of stories of buildings. In contrast, the proposed method using the 2DOF system does not need such selection of the transformation methods and it enables a unified evaluation of the maximum deformation in the base-isolated story regardless of the number of stories.…”
Section: Discussionsupporting
confidence: 53%
“…It can be observed from Figure 14 that the proposed method by using the equivalent 2DOF model and the approximate solution can evaluate the plastic deformation amplitude in the base-isolation story under the critical multiple impulse with reasonable accuracy. The proposed method enables a unified evaluation of the steady-state response in the base-isolation story regardless of the number of stories, although the different procedures depending on the number of stories were necessary in the previous method where the closed-form solution for the SDOF is applied to the base-isolated building (Takewaki et al, 2017).…”
Section: Application Of Approximate Solution To Base-isolated Buildingmentioning
confidence: 99%
“…It should be pointed out that their approach does not need to solve the equation of motion directly. These theories using double and multi impulses are expanded for the elastic-plastic model with linear viscous damping (Kojima et al., 2017; Hayashi et al., 2018, Akehashi et al., 2018), the elastic-plastic 2DOF model (Taniguchi et al, 2016) and the elastic-plastic base-isolated building model (Fujita et al, 2017; Takewaki et al, 2017).…”
Section: Introductionmentioning