2008
DOI: 10.1017/s0263034608000554
|View full text |Cite
|
Sign up to set email alerts
|

Cryogenic systems for inertial fusion energy

Abstract: The Low Temperatures Laboratory of CEA/Grenoble (France) is involved in the development of cryogenic systems for inertial fusion since a ten of years. A conceptual design for the cryogenic infrastructure of the Laser MegaJoule (LMJ) facility has been proposed. Several prototypes have been designed, built and tested like for example the 1500 bars cryo compressor for the targets filling, the target positioner and the thermal shroud remover.The HIPER project will necessitate the development of such equipments. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0
1

Year Published

2009
2009
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 7 publications
0
5
0
1
Order By: Relevance
“…Отметим, что гексапод фирмы Ste Symetrie успешно испытан в системе доставки и позициониро-вания криогенных сферических мишеней в камере мощной лазер-ной установки LMJ [50]. Эти испы-тания показали реальную возмож-ность применения гексапода для позиционирования с высокой точностью (линейная 5 мкм, угловая 50 мкрад) криогенной мишени, находящейся при температуре 18,2 К в центре экспериментальной ва-куумной камеры диаметром 10 м. При этом обеспечивалось максимальное линейное X-Y-Z-перемещение мишени в центре камеры в пределах 50 мм.…”
Section: проблемы доставки и позиционирования криогенной цилиндрическunclassified
“…Отметим, что гексапод фирмы Ste Symetrie успешно испытан в системе доставки и позициониро-вания криогенных сферических мишеней в камере мощной лазер-ной установки LMJ [50]. Эти испы-тания показали реальную возмож-ность применения гексапода для позиционирования с высокой точностью (линейная 5 мкм, угловая 50 мкрад) криогенной мишени, находящейся при температуре 18,2 К в центре экспериментальной ва-куумной камеры диаметром 10 м. При этом обеспечивалось максимальное линейное X-Y-Z-перемещение мишени в центре камеры в пределах 50 мм.…”
Section: проблемы доставки и позиционирования криогенной цилиндрическunclassified
“…Further progress in inertial fusion and high energy density physics in general will greatly depend on the development of efficient targets. Therefore, worldwide experimental and theoretical efforts on target design and simulation are in progress (Aleksandrova et al, 2008;Borisenko et al, 2008;Bret & Deutsch, 2006;Chatain et al, 2008;Deutsch et al, 2008;Eliezer et al, 2007;Foldes & Szatmari, 2008;Hoffmann, 2008;Holmlid et al, 2009;Hora, 2007;Imasaki & Li, 2007;Koresheva et al, 2009;Ramis et al, 2008;Rodriguez et al, 2008;Strangio et al, 2009;Winterberg, 2008;Yang et al, 2008). In order to increase the hohlraum coupling efficiency of a capsule, which is the ratio of absorbed energy to input laser energy, for indirectly driven inertial confinement fusion (ICF), target designers have changed the hohlraum design from pure gold, to one consisting of a mixture of high Z materials ("cocktail") (Dewald et al, 2008;Jones et al, 2007;Orzechowski et al, 1996).…”
Section: Introductionmentioning
confidence: 99%
“…Since the hohlraum target plays a key role in the study of indirect drive inertial fusion study, the experimental and theoretical target design, and simulation continuously attract extensive interests and efforts worldwide (Aleksandrova et al, 2008;Atzeni & Meyer-Ter-vehn, 2004;Borisenko et al, 2008;Bret & Deutsch, 2006;Chatain et al, 2008;Deutsch et al, 2008;Eliezer et al, 2007;Foldes & Szatmari, 2008;Hoffmann, 2008;Holmlid et al, 2009;Hora, 2007;Imasaki & Li, 2007;Koresheva et al, 2009;Li et al, 2010;Ramis et al, 2008;Rodriguez et al, 2008;Strangio et al, 2009;Winterberg, 2008;Yang et al, 2008). The optimal size of a hohlraum is a trade-off between the requirements for energy and power, and the need for symmetry and acceptable plasma filling.…”
Section: Introductionmentioning
confidence: 99%