2018
DOI: 10.1016/j.ejrad.2018.02.015
|View full text |Cite
|
Sign up to set email alerts
|

Cumulative effective dose and cancer risk for pediatric population in repetitive full spine follow-up imaging: How micro dose is the EOS microdose protocol?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 15 publications
0
12
0
1
Order By: Relevance
“…In order to estimate the excessive risk of radiation-induced cancer, the cumulative dose of the study population is required. The number of radiographs per year in the current society was extracted from previous studies [3] , [4] , [5] . Data on the cumulative effective dose for eight radiographs using of scientific relationships based on the acceptance of linear no-threshold model were obtained.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…In order to estimate the excessive risk of radiation-induced cancer, the cumulative dose of the study population is required. The number of radiographs per year in the current society was extracted from previous studies [3] , [4] , [5] . Data on the cumulative effective dose for eight radiographs using of scientific relationships based on the acceptance of linear no-threshold model were obtained.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…It is not straightforward to use the PCXMC Monte Carlo algorithm to calculate the effective doses for the slot scanner based beam compared to the conventional X-ray exposure. Thus, the effective dose calculations in MDSS for the chest protocol were obtained using the method described by 25,26 . The 7 beam width and length are 400 mm x 0.5 mm and 360 mm x 0.5 mm for the chest PA and lateral projections respectively.…”
Section: Pcxmc Simulationsmentioning
confidence: 99%
“…9 Several studies reported a significant association between exposure to high-dose radiation and increased risk of cortical and posterior subcapsular cataract formation or other lenticular changes. 10,11 A CT scan protocol is typically designed to reliably achieve high-quality images for diagnosing all types of brain diseases. Hence, development of low-dose CT scans can reduce patient radiation exposure, which is particularly important for the diagnosis of ICH.…”
Section: Introductionmentioning
confidence: 99%