2015 9th International Conference on Compatibility and Power Electronics (CPE) 2015
DOI: 10.1109/cpe.2015.7231081
|View full text |Cite
|
Sign up to set email alerts
|

Current error space vector based constant switching frequency hysteresis controller for VSI fed Induction Motor drives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Hysteresis controller is one of the most preferred technique used for all the applications of current controlled and voltage source inverters. It exhibit very good dynamical properties as well as robustness, property of inherent peak current limiting and simple hardware implementation makes it most popular [10] [11]. The bandwidth of the hysteresis current controller computed by comparing the load current with the reference current using hysteresis comparators as shown in fig.1 By varying in the inverter operating frequency current waveform can be compensated.…”
Section: Hysteresis Current Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…Hysteresis controller is one of the most preferred technique used for all the applications of current controlled and voltage source inverters. It exhibit very good dynamical properties as well as robustness, property of inherent peak current limiting and simple hardware implementation makes it most popular [10] [11]. The bandwidth of the hysteresis current controller computed by comparing the load current with the reference current using hysteresis comparators as shown in fig.1 By varying in the inverter operating frequency current waveform can be compensated.…”
Section: Hysteresis Current Controllermentioning
confidence: 99%
“…From the definition of the Lyapunov function or energy Function if in each state it is possible to find out a control law to reduce the energy of the system, it is possible to bring the energy of the system to zero, i.e., to bring the system to a stop which means the stable condition of the system. (11) Derivative of V is always zero or negative and gives the Lyapunov (12) i ref is the reference output tracked by using PI controller (13) The gain of PI controller are given as ,…”
Section: Modeling Of Partial Linear Feedback Systemmentioning
confidence: 99%
“…Among these current controllers, the hysteresis band (HB) current controller features inherent current limiting capability, robustness, no modulation stage and simple implementation, in addition to the excellent dynamic and tracking performance [4]. The HB controller has been mainly used in the VSI, and active research on this includes constant switching frequency control [5], online computation of bands [6] and multi‐band hysteresis control [7, 8]. In [9], a comparative study of fixed‐band and sinusoidal‐band hysteresis current controllers (F‐HB and S‐HB) was carried out for VSIs; however, HBs are impractical and the comparison needs further evaluation for various bandwidths and sampling frequencies.…”
Section: Introductionmentioning
confidence: 99%
“…Among these current controllers, the hysteresis band (HB) current controller features inherent current limiting capability, robustness, no modulation stage, and simple implementation, in addition to the excellent dynamic performance. The HB control has been constrained to the VSI and active research on this includes constant switching frequency control [4], online computation of bands [5], and multi-band hysteresis control [6]. For a high inertia system that requires dynamic braking, the VSI based drive system usually requires a rectifier stage to supply the DC voltage and the braking chopper to absorb the kinetic energy generated from the motor deceleration as shown in Fig.…”
Section: Introductionmentioning
confidence: 99%