2019
DOI: 10.1002/pssa.201800869
|View full text |Cite
|
Sign up to set email alerts
|

Customized 2D Structures for High Throughput Electromigration Measurements

Abstract: Customized 2D wires are designed for high throughput electromigration testing on model Al and Cu thin films. Two direct writing approaches for defining the 2D wires are compared with photolithography. Electromigration effects on Al and Cu thin films are studied on 2D wires obtained applying both methods. A self‐developed four‐point probe is used to apply current through the test wires while measuring the potential drop along the wires. Photolithography is selected as the main method to outline the wires in ord… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
12
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(14 citation statements)
references
References 24 publications
(37 reference statements)
2
12
0
Order By: Relevance
“…Here, a rather narrow region on the Cu–Ga library reaches j max values in an excess of 1.6 MA cm –2 , while the value measured on pure Cu test wires remains slightly below 1.2 MA cm –2 . 51 This increase of the ability to withstand electromigration can again be linked to the same 2D transition threshold discussed before for alloys with thickness below 250 nm. Screening the j max mapping resulted in identification of Cu-5 at.…”
Section: Resultssupporting
confidence: 59%
See 4 more Smart Citations
“…Here, a rather narrow region on the Cu–Ga library reaches j max values in an excess of 1.6 MA cm –2 , while the value measured on pure Cu test wires remains slightly below 1.2 MA cm –2 . 51 This increase of the ability to withstand electromigration can again be linked to the same 2D transition threshold discussed before for alloys with thickness below 250 nm. Screening the j max mapping resulted in identification of Cu-5 at.…”
Section: Resultssupporting
confidence: 59%
“…Droplets of the molten material can be observed around the failure line, most likely as a result of the local temperature increase by the Joule effect. 51 Both anodic (on the left side) and cathodic (on the right side) regions are clearly visible, each having its own damage front more accentuated toward the middle of the test line. The magnified image of the anodic damage front presents a snapshot into dynamics of the grain evolution occurring during the electromigration.…”
Section: Resultsmentioning
confidence: 98%
See 3 more Smart Citations