1998
DOI: 10.1016/s0956-5663(98)00004-9
|View full text |Cite
|
Sign up to set email alerts
|

Cyanide determination by an ISFET-based peroxidase biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
1

Year Published

2001
2001
2014
2014

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(21 citation statements)
references
References 5 publications
0
20
1
Order By: Relevance
“…The biocompatibility, the permeability and the electron transfer efficiency within the immobilized matrix are the main factors affecting the activity of immobilized enzymes and consequently the biosensor performance. For example, cyanide biosensors have been developed that are based on the immobilization of HRP on the electrode surface by simple adsorption (Bogdanovskaya et al, 1994;Tatsuma and Oyama, 1996;Zhao et al, 1996), by BSA cross-linking (Smit and Cass, 1990) and by entrapment into a sol-gel matrix (Park et al, 1997) or into a positively charged polymer (Volotovsky and Kim, 1998). The detection limits vary between 10 −7 and 10 −5 M depending on the nature of the immobilization.…”
Section: Introductionmentioning
confidence: 99%
“…The biocompatibility, the permeability and the electron transfer efficiency within the immobilized matrix are the main factors affecting the activity of immobilized enzymes and consequently the biosensor performance. For example, cyanide biosensors have been developed that are based on the immobilization of HRP on the electrode surface by simple adsorption (Bogdanovskaya et al, 1994;Tatsuma and Oyama, 1996;Zhao et al, 1996), by BSA cross-linking (Smit and Cass, 1990) and by entrapment into a sol-gel matrix (Park et al, 1997) or into a positively charged polymer (Volotovsky and Kim, 1998). The detection limits vary between 10 −7 and 10 −5 M depending on the nature of the immobilization.…”
Section: Introductionmentioning
confidence: 99%
“…However, research is continuing to overcome these problems. Many designs have been suggested for EnFET biosensors [76,77,78,79,80,81,82,83], as well as other forms of FET-based biosensors (e.g. ImmunoFET, GenFET, cell-based FET, etc.…”
Section: Field-effect Transistor (Fet)mentioning
confidence: 99%
“…In 1980, Caras and Janata showed the practical applicability of an ISFET as a pH-based enzyme FET for the measurement of penicillin [13]. Subsequently, many designs were suggested for enzyme-FET biosensors [28][29][30][31].…”
Section: Fet Basicsmentioning
confidence: 99%