2016
DOI: 10.1002/elps.201600120
|View full text |Cite
|
Sign up to set email alerts
|

CZE determination of submicromolar level of phenol in seawater using improved dynamic pH junction

Abstract: Using an improved dynamic pH junction as an on-line concentration procedure, we developed CZE for determining submicromolar phenol in seawater for chloride to phenol concentration ratios of 1 000 000. To enhance the effect of conventional dynamic pH junction, a saturated fatty acid solution was injected into the capillary after sample injection. We named the procedure an improved dynamic pH junction. The method requires no sample pretreatment. The following optimum conditions were established: BGE, 40 mM sodiu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 25 publications
0
9
0
Order By: Relevance
“…A simulation study performed with the same simulator dealt with the concentration of weak acids in a pH boundary formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 electrolytes [140]. Other input data are given in [144]. From ref.…”
Section: Zone Electrophoresis Isotachophoresis Moving Boundaries and ...mentioning
confidence: 99%
See 1 more Smart Citation
“…A simulation study performed with the same simulator dealt with the concentration of weak acids in a pH boundary formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 electrolytes [140]. Other input data are given in [144]. From ref.…”
Section: Zone Electrophoresis Isotachophoresis Moving Boundaries and ...mentioning
confidence: 99%
“…A 50 μm id capillary of 50 mm length divided by a mesh of 10 μm without EOF served as separation space. Other input data are given in[144]. From ref [144]…”
mentioning
confidence: 99%
“…Yasuno and Fukushi developed an improved dynamic pH junction to determine sub‐micromolar phenol in seawater. They used borate buffer at pH 9.8 (close to the p K a of phenol) and hexadimethrine bromide to reverse EOF.…”
Section: Stackingmentioning
confidence: 99%
“…However, the concentration sensitivity of CE with conventional UV detection is not sufficiently high because of the-small sample-injection volume and the short light pathway. Therefore, various on-line concentration procedures have been developed to improve the sensitivity: field-amplified sample injection (FASI) [13][14][15][16][17], large volume sample stacking [18,19], dynamic pH junction [20][21][22], sweeping [23,24], electrokinetic supercharging (EKS) [25][26][27], and transient isotachophoresis (tITP) [17,28].…”
Section: Introductionmentioning
confidence: 99%