2020
DOI: 10.1016/j.aanat.2020.151511
|View full text |Cite
|
Sign up to set email alerts
|

Definition of a drilling protocol for mini dental implants in different bone qualities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
2
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 20 publications
1
2
0
2
Order By: Relevance
“…Therefore, the findings from this study corroborate the recommendation from the manufacturer to utilize site‐specific drilling protocols, according to the bone site density 19 . This clinical data is also in agreement with a previous in vitro study which evaluated drilling protocols for mini implants, where bone quality was a major determinant of final insertion torque, independent of the protocol used 17 . Therefore, careful attention should be paid to the use of the needle and pilot drills, and depth of preparation.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…Therefore, the findings from this study corroborate the recommendation from the manufacturer to utilize site‐specific drilling protocols, according to the bone site density 19 . This clinical data is also in agreement with a previous in vitro study which evaluated drilling protocols for mini implants, where bone quality was a major determinant of final insertion torque, independent of the protocol used 17 . Therefore, careful attention should be paid to the use of the needle and pilot drills, and depth of preparation.…”
Section: Discussionsupporting
confidence: 90%
“…19 This clinical data is also in agreement with a previous in vitro study which evaluated drilling protocols for mini implants, where bone quality was a major determinant of final insertion torque, independent of the protocol used. 17 Therefore, careful attention should be paid to the use of the needle and pilot drills, and depth of preparation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Las ecuaciones (23) y (24) presentan el momento flector en los planos yx y yz, para generar los diagramas de momento en la figura 5. El cortante resultante, V2, se obtiene con la ecuación (25), y el momento flector resultante M2 con la ecuación (26). El diagrama de momento torsor T2 se muestra en la figura 6, generado a partir de la ecuación (27), donde Y: distancia a lo largo del eje en milímetros, Tins2: torque de entrada al eje 2, Tins3: torque de entrada al eje 3. mm.…”
Section: Dimensionamiento De Ejesunclassified
“…En otro contexto, Dorsam et al [26] han definido un protocolo para inserción de mini implantes dentales de acuerdo con las propiedades del hueso y al tamaño del tornillo, pero no usan un banco o dispositivo. También recientemente, se ha evaluado a relación entre el torque de inserción de mini implantes dentales y la integridad de superficie en tornillos de zirconio titanio, pero usando un dinamómetro manual [27].…”
Section: Introductionunclassified