Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness

Abstract: DCT and GAT measurements are conditioned by PCT though this effect, rather than linear, follows a 2-degree polynomial pattern.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 38 publications
0
6
0
2
Order By: Relevance
“…However, as IOP is measured through the cornea, readings are affected by characteristics of the cornea such as corneal curvature, thickness and biomechanics [ 4 , 5 ]. Measurements of central corneal thickness (CCT) and corneal biomechanical properties such as corneal hysteresis provide useful additional information for risk profiling but also have a confounding effect on the measurement of IOP [ 2 , 6 , 7 , 8 , 9 , 10 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, as IOP is measured through the cornea, readings are affected by characteristics of the cornea such as corneal curvature, thickness and biomechanics [ 4 , 5 ]. Measurements of central corneal thickness (CCT) and corneal biomechanical properties such as corneal hysteresis provide useful additional information for risk profiling but also have a confounding effect on the measurement of IOP [ 2 , 6 , 7 , 8 , 9 , 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…Goldmann applanation tonometry (GAT) remains widely regarded as the gold standard method of IOP measurement [ 6 , 11 , 12 , 13 , 14 , 15 ], but a range of newer devices are available including non-contact tonometry (NCT), rebound tonometry (RT) and dynamic contour tonometry (DCT) [ 6 , 7 , 8 , 9 , 11 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 ]. NCT uses an air puff that deforms the cornea, with the advantage of not requiring anesthetic eye drops [ 8 , 21 , 26 , 29 ]; RT assesses IOP by firing a small plastic-tipped probe at the surface of the cornea, with the speed at which the probe returns to its initial position providing information on IOP [ 22 , 23 , 30 , 31 , 32 ]; and DCT uses a slit lamp mounted device containing a pressure sensor.…”
Section: Introductionmentioning
confidence: 99%
“…For example, for such defined vibrations, a comparative analysis with patients with keratoconus or glaucoma can be performed. Any change in the biomechanical conditions of the cornea and in particular corneal thickness [ 32 , 80 86 ] affects the measured biomechanical parameters of vibrations. Evaluation of the effect of these diseases on the obtained results and their diagnostic usefulness will be the subject of subsequent authors' papers.…”
Section: Discussionmentioning
confidence: 99%
“…Elena JORDANOVA 1 , Paraskeva HENTOVA-SENCANIC 2 , Ivan MARJANOVIC 3,4 , Ivan SENCANIC, Ivana STEFANOVIC 6 , Marko BARALIC 7…”
Section: Original Articleunclassified
“…Tetrakain hlorid 1%. Vršena su tri uzastopna merenja, na ekranu pahimetra očitavana je srednja vrednost CCT izražene u μm [3,6]. Izvršena je podela vrednosti CCT u tri podgrupe: tanka rožnjača (485-519 μm), rožnjača srednje debljine (520 do 589 μm) i debela rožnjača od 590-684 μm.…”
unclassified