Design and Characterization of a Novel Knee Articulation Mechanism

Abstract: The paper is focused on designing a novel controllable and adjustable mechanism for reproducing human knee joint's complex motion by taking into account the flexion/extension movement in the sagittal plane, in combination with roll and slide. Main requirements for a knee rehabilitation supporting device are specified by researching the knee's anatomy and already existing mechanisms. A three degree of freedom (3 DOF) system (four-bar like linkage with controlled variable lengths of rockers) is synthesised to pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 12 publications
0
9
0
Order By: Relevance
“…Thus, the response of the system is obtained by properly assigning the causal strokes. 22 In this work, the actuator and the motor lie in the electrical domain, whereas the gearbox, lead screw, and four-bar mechanism exist in the mechanical domain. Such multidomain systems can easily be modelled using BG and the work shows useful application of this technique.…”
Section: Bg Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, the response of the system is obtained by properly assigning the causal strokes. 22 In this work, the actuator and the motor lie in the electrical domain, whereas the gearbox, lead screw, and four-bar mechanism exist in the mechanical domain. Such multidomain systems can easily be modelled using BG and the work shows useful application of this technique.…”
Section: Bg Modelsmentioning
confidence: 99%
“…A linear actuator for the actuation purpose was utilized for the actuation. Olinski et al 22 proposed a 3-DOF system to perform the reference path of ICR of knee joint. The device was based on four-bar mechanism having controlled variable lengths of rockers for knee joint rehabilitation of the wearer.…”
Section: Introductionmentioning
confidence: 99%
“…The materials for implants should be of low Young's modulus (as close to the bone elasticity as possible), and low weight density. Titanium and its alloys with niobium [14,16] present those features. When Young's modulus value is close to the one of the bone being implanted (tibia or femoral) it very positively influences on bio-compatibility of the alloplastics.…”
Section: Stress Analysis In the Pair Sled -Flat Insert For Endoprosthmentioning
confidence: 99%
“…There are currently being tested new titanium alloys with niobium and zirconium with much lower elasticity modulus of 55-60 GPa. Titanium alloys like Ti6Al4V and new ones like TiNbZr and TiNbZrTa, present very good mechanical features, however lower value of elasticity modulus of the alloys with niobium proves that the future of alloplastics belongs to them [12,13,14].…”
Section: Stress Analysis In the Pair Sled -Flat Insert For Endoprosthmentioning
confidence: 99%
“…This system is characterized by spatial movable relations between particular bones of the lower and upper limbs. In the case of the lower limb, the most common number is the 7 degrees of freedom between the pelvis and the foot of each limb (Olinski, 2016). This means that the lower limb forms a redundant system thanks to which the mobility of the entire limb is increased.…”
Section: Introductionmentioning