Design and characterization of Stormram 4: An MRI-compatible robotic system for breast biopsy

Abstract: Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able to target lesions with high precision and direct feedback of MRI. Therefore, the design and working mechanism of the new Stormram 4, an MRI-compatible needle manipulator with four degrees of freedom, will be presen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
2
2

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 9 publications
0
18
0
Order By: Relevance
“…Besides the motors presented in this paper, two other novel motors that meet the stated requirements are published by the same authors [20]. The T-26 is a further miniaturized version of the T-63 presented in this paper, while the C-30 is a curved stepper motor similar to the T-26 but in which the rack is curved to make a rotational motion.…”
Section: A State Of the Artmentioning
confidence: 99%
“…Besides the motors presented in this paper, two other novel motors that meet the stated requirements are published by the same authors [20]. The T-26 is a further miniaturized version of the T-63 presented in this paper, while the C-30 is a curved stepper motor similar to the T-26 but in which the rack is curved to make a rotational motion.…”
Section: A State Of the Artmentioning
confidence: 99%
“…Pneumatic stepper motors have been proved an effective actuation method in several state-of-art robotic systems [1,2] . These systems are limited in bandwidth as 5 m long pneumatic tubes are needed between the valve manifold and the robotic system.…”
Section: Introductionmentioning
confidence: 99%
“…The Stormram 4 needs approximately one minute to move from one position to another considering an axis of 640 steps. Higher velocities are desirable for practical applications [2] .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides the motors presented in this paper, two other novel motors that meet the stated requirements are published by the same authors [50]. The T-26 is a further miniaturized version of the T-63 presented in this paper, while the C-30 is a curved stepper motor similar to the T-26 but in which the rack is curved to make a rotational motion.…”
Section: State Of the Artmentioning
confidence: 99%