Design and control of hybrid actuation lower limb exoskeleton

Abstract: In this article, two types of actuators are applied for a lower limb exoskeleton. They are DC motors with the harmonic drive and the pneumatic artificial muscles. This combination takes advantages of both the harmonic drive and the pneumatic artificial muscle. It provides both high accuracy position control and high ratio of strength and weight. The shortcomings of the two actuators are overcome by the hybrid actuation, for example, low control accuracy and modeling difficult of pneumatic artificial muscle, co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(30 citation statements)
references
References 12 publications
0
28
0
2
Order By: Relevance
“…This is because when a load was added to the bar (i.e., to the output shaft of the gearbox), the torque transmitted to the input shaft in the gear of G05P1-2 was twice the torque of the gear of G10P1-2. Therefore, the PAMs of G05P1-2 were pulled by double the force and stretched longer compared with G10P1-2, as shown in Equation (2). The longer stretch made the input and output shaft rotate more.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…This is because when a load was added to the bar (i.e., to the output shaft of the gearbox), the torque transmitted to the input shaft in the gear of G05P1-2 was twice the torque of the gear of G10P1-2. Therefore, the PAMs of G05P1-2 were pulled by double the force and stretched longer compared with G10P1-2, as shown in Equation (2). The longer stretch made the input and output shaft rotate more.…”
Section: Discussionmentioning
confidence: 99%
“…The change of length with respect to the unloaded natural length of each PAM piece, that is to say, lc, was measured under each weight, and the measurements were repeated 10 times. The resulting relational expression is shown in Equation (2). The correlation coefficient for approximation of the relationship between the Ft and lc in Figure 3d was −0.9971.…”
Section: Pneumatic Artificial Muscle (Pam)mentioning
confidence: 99%
See 2 more Smart Citations
“…Intensive and long rehabilitation training process should be carried out with the help of clinical professionals and operational therapists (OTs) for the final recovery of delicate and subtle movements of hand and finger. 3,4 Clinicians involved must pay full attention to identify correct hand gestures while manually aiding as needed with awareness, verbal guidance, and assistance during the whole training process. This training process is effective when it conducts repetitively.…”
Section: Introductionmentioning
confidence: 99%