2015 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON) 2015
DOI: 10.1109/chilecon.2015.7400429
|View full text |Cite
|
Sign up to set email alerts
|

Design and implementation of a gateway between IEC 61850 and IEC 60870-5-101 standards for power electrical systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 9 publications
0
1
0
1
Order By: Relevance
“…Switch and recloser devices each have a set of unique data points which correspond to the asset’s current operational status, communicated to the DSO’s SCADA system via a wirelessly enabled Remote Terminal Unit (RTU) employing the International Electrotechnical Commission (IEC) protocol standard, IEC 60870-5-101/104 17 . Through this protocol, the data points map to an information object address (IOA), and the devices are identifiable through a unique application service data unit (ASDU) type 18 . Two data points that match FPI and LVI were identified for both switches and reclosers, described with their corresponding IOA value in Table 3 .…”
Section: Methodsmentioning
confidence: 99%
“…Switch and recloser devices each have a set of unique data points which correspond to the asset’s current operational status, communicated to the DSO’s SCADA system via a wirelessly enabled Remote Terminal Unit (RTU) employing the International Electrotechnical Commission (IEC) protocol standard, IEC 60870-5-101/104 17 . Through this protocol, the data points map to an information object address (IOA), and the devices are identifiable through a unique application service data unit (ASDU) type 18 . Two data points that match FPI and LVI were identified for both switches and reclosers, described with their corresponding IOA value in Table 3 .…”
Section: Methodsmentioning
confidence: 99%
“…Pada station level, server digunakan untuk mengambil data (status, pengukuran, dan kontrol) dari IED-IED lewat protokol IEC 61850, sedangkan workstation (HMI / Human Machine Interface) digunakan untuk menampilkan data-data yang sudah dikumpulkan oleh server. Gateway merupakan protocol converter, pada satu sisi menggunakan protokol IEC 61850 dan di sisi lain menggunakan protokol yang lain (contohnya IEC 60870-5-101) [10]. Gateway ini digunakan untuk mengambil data (status, pengukuran, dan kontrol) dari IED-IED menggunakan protokol IEC 61850 dan dikirimkan melalui protokol IEC 60870-5-101 atau IEC 60870-5-104 atau DNP3.…”
Section: Pendahuluanunclassified
“…Pada station level, server digunakan untuk mengambil data (status, pengukuran, dan kontrol) dari IED-IED lewat protokol IEC 61850, sedangkan workstation digunakan untuk menampilkan data-data yang sudah dikumpulkan oleh server. Gateway merupakan protocol converter, pada satu sisi menggunakan protokol IEC 61850 dan di sisi lain menggunakan protokol yang lain (contohnya IEC 60870-5-101) [10]. Gateway ini digunakan untuk mengambil data (status, pengukuran, dan kontrol) dari IED-IED lewat protokol IEC 61850 dan dikirimkan melalui protokol IEC 60870-5-101 atau IEC 60870-5-104 atau DNP3.…”
Section: Gambar 1 Goose Messageunclassified