2020
DOI: 10.1016/j.conengprac.2020.104494
|View full text |Cite
|
Sign up to set email alerts
|

Design and implementation of fuzzy logic based modified real-reactive power control of inverter for low voltage ride through enhancement in grid connected solar PV system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(23 citation statements)
references
References 25 publications
1
17
0
1
Order By: Relevance
“…The system produces a good quality of energy with active power only. The PI controller optimized by the genetic algorithm gives 0.89% of the total harmonic distortion (THD) less than 1.97% obtained in [22]. This value of THD satisfies the standard value given by NF C 15-100 and IEEE 519 (T HD <5%) [15], [27], [28].…”
Section: Resultssupporting
confidence: 60%
See 2 more Smart Citations
“…The system produces a good quality of energy with active power only. The PI controller optimized by the genetic algorithm gives 0.89% of the total harmonic distortion (THD) less than 1.97% obtained in [22]. This value of THD satisfies the standard value given by NF C 15-100 and IEEE 519 (T HD <5%) [15], [27], [28].…”
Section: Resultssupporting
confidence: 60%
“…Figure 12 (a) shows the deference between the proposed method and PI Classique. In Figure 12 (b), it is noted clearly that the GA-PI is better than the PI method witch parameters are determined by Ziegler method and the adaptive neural network used in [22]. proposed method gave a low total harmonic distortion (0.89%) and it is better than the conventional methods (Ziegler-Nicolson, and Naslin) used to determine the parameters of the correctors.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…generación fotovoltaica, como se presenta en (Loukil et al, 2020) y (Roselyn et al, 2020), respectivamente.…”
Section: Estado Del Arteunclassified
“…Moreover, the increasing integration of PV plants with electrical grids has motivated many researchers to analyze the stability of such systems, especially during grid faults [3][4][5][6]. For example, [3] analyzed different low voltage ride through (LVRT) control algorithms, whereas [4] applied fuzzy logic to control the active and reactive power in LVRT control systems to improve system stability. The authors in [5] introduced LVRT to a grid-connected PV system and used a battery to mitigate DC-link voltage variation.…”
mentioning
confidence: 99%