2023
DOI: 10.1088/2058-6272/acaf61
|View full text |Cite
|
Sign up to set email alerts
|

Design and platform testing of the compact torus central fueling device for the EAST tokamak

Abstract: Compact Tours (CT) injection is a highly promising technique for the central fueling of future reactor-grade fusion devices since it features extremely high injection velocity and relatively high plasma mass. Recently, a CT injector for the EAST tokamak, EAST-CTI, was developed and platform-tested. In the first round of experiments conducted with low parameter settings, the maximum velocity and mass of the CT plasma were 150 km·s−1 and 90 µg, respectively. However, the parameters obtained by the EAST-CTI were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 41 publications
0
3
0
Order By: Relevance
“…The experimental results verify its powerful ability for central fueling and also indicate some other beneficial effects, such as high-confinement mode transition and the mitigation of disruptions [6,7]. Recently, a CTI system was designed and built on experimental advanced superconducting tokamak (EAST), which is a medium-sized tokamak with strong magnetic fields (2 ∼ 3 T) [8,9]. The mass and the maximum velocity of the CTI plasma were 90 μg and 150 km•s −1 , respectively, in the first round experiments.…”
Section: Introductionmentioning
confidence: 63%
See 2 more Smart Citations
“…The experimental results verify its powerful ability for central fueling and also indicate some other beneficial effects, such as high-confinement mode transition and the mitigation of disruptions [6,7]. Recently, a CTI system was designed and built on experimental advanced superconducting tokamak (EAST), which is a medium-sized tokamak with strong magnetic fields (2 ∼ 3 T) [8,9]. The mass and the maximum velocity of the CTI plasma were 90 μg and 150 km•s −1 , respectively, in the first round experiments.…”
Section: Introductionmentioning
confidence: 63%
“…The line-averaged electron density was measured by the optical fiber interferometer [31] and about 100-150 × 10 20 m −3 at flat-top stage. The electron temperature is measured by Langmuir probes [8] and relatively low, only around several eV in this round experiment. In the formation region, a high voltage of about 15 kV is generated between the inner electrode and outer electrode to break down the main particle helium, with impurities on the electrodes sputtered out and enter the plasma.…”
Section: Preliminary Experimental Results Of the Vuv Spectrometer On ...mentioning
confidence: 99%
See 1 more Smart Citation