Design and Preliminary Evaluation of a Stiff Steerable Cutter for Arthroscopic Procedures

Abstract: This article describes a novel and simple shaft actuated tip articulation (SATA) mechanism that allows arthroscopic instruments to articulate while remaining stiff. Since the SATA mechanism requires only independent rotation of two tubes for hinge articulation, cables, gears, or other internal components that are normally found in steerable endoscopic instruments become obsolete. The SATA mechanism was integrated in a new steerable cutter prototype and tested. Early user, mechanical strength and cadaver experi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(23 citation statements)
references
References 10 publications
0
23
0
Order By: Relevance
“…Suturing with a curved needle requires a smooth and coupled rotational motion that follows the line of the needle, so it seems relevant to copy the wrist motion of the hand from outside into the abdomen. During other less complex surgical actions, such as cutting a damaged meniscus during a knee arthroscopy, it seems relevant to allow the surgeon to use the steering function only to adjust the tip configuration when following the rim of the meniscus before loose parts are cut and removed [22, 23]. In many other common situations, there is a need to line up the beak of the instrument with the tissue to be manipulated (e.g.…”
Section: Actuation Principlesmentioning
confidence: 99%
See 4 more Smart Citations
“…Suturing with a curved needle requires a smooth and coupled rotational motion that follows the line of the needle, so it seems relevant to copy the wrist motion of the hand from outside into the abdomen. During other less complex surgical actions, such as cutting a damaged meniscus during a knee arthroscopy, it seems relevant to allow the surgeon to use the steering function only to adjust the tip configuration when following the rim of the meniscus before loose parts are cut and removed [22, 23]. In many other common situations, there is a need to line up the beak of the instrument with the tissue to be manipulated (e.g.…”
Section: Actuation Principlesmentioning
confidence: 99%
“…This can be accomplished by developing intuitive and maintenance-friendly instrumentation that can be used by surgeons working in poorly resourced hospitals with basic CSSDs. We have, therefore, used a “bare-minimum design” methodology, with a strong focus on component interaction analysis and adding functions to standard components [22], in combination with a stepwise development and evaluation plan that involves all key users who come into contact with the innovation to create a new steering mechanism.…”
Section: Complexity Of Steerable Instrumentsmentioning
confidence: 99%
See 3 more Smart Citations