2019
DOI: 10.1007/s42235-019-0045-0
|View full text |Cite
|
Sign up to set email alerts
|

Design and Simulation of a Novel Pneumotronic System Aimed to the Investigation of Vascular Phenomena Induced by Limb Compression

Abstract: Intermittent Pneumatic Compression (IPC) devices can be used to analyze the mechanisms underlying several vascular phenomena, such as hyperaemia. Commercial devices have limited dynamics and do not allow the delivery of customizable compressive pressure patterns, making difficult the analysis of such phenomena, which may require the application of long stimulations with low amplitude as well as fast compressions with higher pressure level. To overcome these issues, a novel pneumo-tronic device aimed to the in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…Expensive professional machines are generally adopted to the purpose of eliciting rapid tissue compressions [13]. We faced this need when investigating the muscular and skin reactivity to compressive stimuli [14,15], and developed a custom system on the basis of PC-driven valves for controlled rapid inflation and deflation of the cuff [14,16], as recently reviewed [17]. For the present application, a single 3-way valve was adopted for both inflation and deflation.…”
Section: Discussionmentioning
confidence: 99%
“…Expensive professional machines are generally adopted to the purpose of eliciting rapid tissue compressions [13]. We faced this need when investigating the muscular and skin reactivity to compressive stimuli [14,15], and developed a custom system on the basis of PC-driven valves for controlled rapid inflation and deflation of the cuff [14,16], as recently reviewed [17]. For the present application, a single 3-way valve was adopted for both inflation and deflation.…”
Section: Discussionmentioning
confidence: 99%
“…The cuff inflation was operated by two solenoid valves (VXE2330-02F-6D01, SMC, Tokyo, Japan), granting rapid in-flow and out-flow, and a proportional valve (ITV0010, SMC, Tokyo, Japan), granting precise pressure maintenance at the desired level. Compressed air (1 bar) was provided by an air compressor, and the Spike2 software (version 9, Cambridge Electronic Design, Cambridge, UK) coupled with an I/O board (CED Micro 1041, Cambridge Electronic Design, Cambridge, UK) was used to drive the above-mentioned valves to implement both rapid and slow inflation/deflation patterns 12 14 .…”
Section: Methodsmentioning
confidence: 99%
“…where X is the feature layer of the convolution output, 1 ≤ i ≤ h, 1 ≤ j ≤ w and the implementation principle is shown in Figure 10. The gradient of equation 9is calculated as equation (10) and equation (11).…”
Section: B Activation Functionmentioning
confidence: 99%
“…About 23% of adults suffer from varicose veins of the lower extremities, and the current number has exceeded 25 million [9], [10]. In China, the prevalence of varicose veins has exceeded 8% [11]. In addition to affecting aesthetics, varicose veins can also cause complications, for example, venous edema, skin ulcers and thrombophlebitis, and increase the risk of deep vein thrombosis [12], which can cause disability and the lower labor force.…”
Section: Introductionmentioning
confidence: 99%