1999
DOI: 10.1109/19.769672
|View full text |Cite
|
Sign up to set email alerts
|

Design of a broadband multiprobe reflectometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Starting from these three possible conditions, we chose five loads to optimize the accuracy of the sensing-board algorithm in the area defined by the impedances reported in Figure 9 over the entire bandwidth. In addition, we took into account the condition number of the matrix C [35] to reduce the sensitivity of the calibration algorithm to measurement uncertainty. The selected loads are reported in Table 1, for which the condition number results sufficiently small (~5).…”
Section: Matrixmentioning
confidence: 99%
“…Starting from these three possible conditions, we chose five loads to optimize the accuracy of the sensing-board algorithm in the area defined by the impedances reported in Figure 9 over the entire bandwidth. In addition, we took into account the condition number of the matrix C [35] to reduce the sensitivity of the calibration algorithm to measurement uncertainty. The selected loads are reported in Table 1, for which the condition number results sufficiently small (~5).…”
Section: Matrixmentioning
confidence: 99%
“…The chosen five loads for the calibration of the six-port junction are reported in Table I. These five standards are chosen taking into account the possible values of the antenna input impedance and considering also the conditional number of the matrix C [11]. Indeed, we can link the accuracy of the calibration result and the choice of these five standards with the conditional number of the matrix C. For the loads reported in Table I, the conditional number of the matrix C is 5.…”
Section: Calibration Proceduresmentioning
confidence: 99%
“…They feature very simple structure, however, classic solutions having three probes operate in a narrow bandwidth . This drawback can be overcome by the application of higher number of power detectors arranged nonuniformly along the transmission line . The operational frequency range can be significantly enlarged, at the expense of the measurement conditions for specified frequencies.…”
Section: Introductionmentioning
confidence: 99%