2010
DOI: 10.1016/j.talanta.2009.09.025
|View full text |Cite
|
Sign up to set email alerts
|

Design of a new electrogenerated polyquinone film substituted with glutathione. Towards direct electrochemical biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…Figure 2(a) is one such example of MIP protein sensors. Conducting polymers (CPs), a group of polymers exhibiting good electrical conductivity (10 −11 to 10 3 S/cm with a carrier concentration ranging between 10 12 and 10 19 /cm 3 ), have been used to increase the detection sensitivity of protein detection systems such as FETs [11,81,90,91]. Figure 2(b) displays typical examples of CPs.…”
Section: Polymers Currently Used In Analytical Detection Of Proteinsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 2(a) is one such example of MIP protein sensors. Conducting polymers (CPs), a group of polymers exhibiting good electrical conductivity (10 −11 to 10 3 S/cm with a carrier concentration ranging between 10 12 and 10 19 /cm 3 ), have been used to increase the detection sensitivity of protein detection systems such as FETs [11,81,90,91]. Figure 2(b) displays typical examples of CPs.…”
Section: Polymers Currently Used In Analytical Detection Of Proteinsmentioning
confidence: 99%
“…Conducting polymers have demonstrated their utility as a biosensor material in these applications, although their current utility is limited due to difficulties in device integration and manufacturing using traditional microfabrication processes [11,81,90,91]. …”
Section: Polymers Currently Used In Analytical Detection Of Proteinsmentioning
confidence: 99%
“…The time of modification was 24 h. The GSH molecule has four possibilities for acid dissociation [16]. This tripeptide is characterized by pKa values: 2.1 (glu-COOH), 3.5 (gly-COOH), 8.7 (SH) and 9.6 (NH 2 ) [17]. In the pH range 3-8, -SH group is not dissociated and the molecule bears a net charge À1 or À2, corresponding to the dissociated carboxyl groups and ionized NH 2 group [18].…”
Section: Electrode Modificationmentioning
confidence: 99%
“…Nanostructured CPs as promising materials can be applied in DNA sensors due to its unique functional groups and excellent electron change ability . Compared with metal sensing platform, the major advantage associated with CPs is that they can act as a direct electronic transducer based on self‐signals without any outside indicator . With respect to analysis of DNA sequences, direct and label‐free DNA electrochemical detection seems to be in a dominant position, owing to low cost, simplicity, avoiding contamination to samples and no needing outer indicator or complicated label .…”
Section: Introductionmentioning
confidence: 99%