Design of foldable, responsively drug-eluting polyacrylic intraocular lens bulk materials for prevention of postoperative complications

Abstract: Posterior capsular opacification (PCO), resulting from the undemanded intracapsular cell proliferation, is the most common complication of intraocular lens (IOL) implantation after cataract surgery. In recent years, IOL has become...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 46 publications
0
3
0
Order By: Relevance
“…While the AuNPs@MIL-PGE group was cultured for another 72 h, the number of cells was significantly reduced compared with 24 h and considerably less than the PGE group. This proved that the AuNPs@MIL-PGE material could effectively remove the residual HLECs on the surface while retaining the excellent ability of PGE, whose good functionality of anti-adhesion and anti-cell migration ability has been demonstrated and introduced in detail in our previous work [ 32 ].
Fig.
…”
Section: Resultsmentioning
confidence: 80%
See 1 more Smart Citation
“…While the AuNPs@MIL-PGE group was cultured for another 72 h, the number of cells was significantly reduced compared with 24 h and considerably less than the PGE group. This proved that the AuNPs@MIL-PGE material could effectively remove the residual HLECs on the surface while retaining the excellent ability of PGE, whose good functionality of anti-adhesion and anti-cell migration ability has been demonstrated and introduced in detail in our previous work [ 32 ].
Fig.
…”
Section: Resultsmentioning
confidence: 80%
“…After introducing AuNPs@MIL into the poly (glycidyl methacrylate)-co-2-(2-ethoxyethoxy) ethyl acrylate (PGE) system, novel IOL bulk materials with synergistic therapeutic effects were prepared by radical polymerization. In our previous work [ 31 , 32 ], the reliability of PGE as a novel IOL bulk material was verified. After AuNPs@MIL was doped into the IOL bulk material PGE, the MIL structure could not only prevent the inevitable agglomeration during the preparation of AuNPs but also prevent the deactivation caused by protein adsorption.…”
Section: Introductionmentioning
confidence: 98%
“…To provide our readers with more comprehensive information, we have compiled a list of drugs that can be contained in contact lenses (Table ). ,,− …”
Section: Therapeutic Sclsmentioning
confidence: 99%
“…The first generation of IOL was made of polymethylmethacrylate [ 18 ]. Subsequently, hydrophilic or hydrophobic acrylate polymer with a higher refractive index was developed as the second generation IOL materials, which was foldable and alleviated large cornea incision during the surgery [ [19] , [20] , [21] ]. But, despite all these, the current IOLs are still too stiff to deform with ciliary muscle movements, resulting in fixed focal length and lack the ability to adjust focus for different distances [ 22 , 23 ].…”
Section: Introductionmentioning
confidence: 99%