2005
DOI: 10.4015/s1016237205000287
|View full text |Cite
|
Sign up to set email alerts
|

Designing Low Power of Sigma Delta Modulator for Biomedical Application

Abstract: ABSTRACT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…The solution used here is the delta-modulator ADC algorithm, based on a sigma-delta modulator circuit (Corradi and Indiveri, 2015 ). This mechanism is particularly used in low frequency, high performance and low power applications (Lee et al, 2005 ), such as biomedical circuits. Moreover, this modulator represents a good interface for neuromorphic devices because it has much less circuit complexity and lower power consumption than multi-bit ADCs.…”
Section: Methodsmentioning
confidence: 99%
“…The solution used here is the delta-modulator ADC algorithm, based on a sigma-delta modulator circuit (Corradi and Indiveri, 2015 ). This mechanism is particularly used in low frequency, high performance and low power applications (Lee et al, 2005 ), such as biomedical circuits. Moreover, this modulator represents a good interface for neuromorphic devices because it has much less circuit complexity and lower power consumption than multi-bit ADCs.…”
Section: Methodsmentioning
confidence: 99%
“…Here, we apply a small-world RSNN implemented on the Mosaic to the detection of arrhythmic heartbeats from ECG signals 41 (see Methods). First, we encode the continuous ECG time-series into trains of spikes using a delta-modulation technique, which describes the relative changes in signal magnitude 42,43 . These spikes are then fed as input into the Mosaic small-world RSNN.…”
Section: Application To Ecg Anomaly Detectionmentioning
confidence: 99%
“…The way a signal is collected is seen important when multiple feature extractions from an EEG signal are made by a PXA 270 processor [62,64,73–76]. …”
Section: To Use Modified Ica Capture More Precise Physiological Signalsmentioning
confidence: 99%
“…It is requested that the number of linear mixed measurement signal be no less than that of uncorrelated components, a requirement that cannot be fulfilled in most ICA theoretic analyses and applications. For this sake, the excessive basal Independent component analysis is proposed as a means to address such issue with a higher computational complexity [62,64]. …”
Section: To Use Modified Ica Capture More Precise Physiological Signalsmentioning
confidence: 99%