2008
DOI: 10.1111/j.1556-4029.2008.00752.x
|View full text |Cite
|
Sign up to set email alerts
|

Desorption Electrospray Tandem MS (DESI‐MSMS) Analysis of Methyl Centralite and Ethyl Centralite as Gunshot Residues on Skin and Other Surfaces

Abstract: A direct and sensitive method for the detection of methyl centralite (MC) and ethyl centralite (EC) as gunshot residues (GSRs) has been developed. This method uses desorption electrospray ionization (DESI)-tandem mass spectrometry and directly desorbs and detects analytes from surfaces without any sampling process. Typical transitions for MC and EC, m/z 241 to m/z 134 and m/z 269 to m/z 148, respectively, were used to improve the assay sensitivity. It has been shown that MC and EC can be detected on various su… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
58
1

Year Published

2008
2008
2016
2016

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 62 publications
(60 citation statements)
references
References 27 publications
1
58
1
Order By: Relevance
“…The evidential value of this technique would significantly increase with the inclusion of several additional OGSR compounds. The authors stated, however, that the capability for this is present, based on previous studies that used DESI-MS for the detection of for example diphenylamine (DPA) and its nitration products from propellant powders [68,69].…”
Section: Desorption Electrospray Ionisationmentioning
confidence: 99%
See 3 more Smart Citations
“…The evidential value of this technique would significantly increase with the inclusion of several additional OGSR compounds. The authors stated, however, that the capability for this is present, based on previous studies that used DESI-MS for the detection of for example diphenylamine (DPA) and its nitration products from propellant powders [68,69].…”
Section: Desorption Electrospray Ionisationmentioning
confidence: 99%
“…The major advantages associated with desorption electrospray ionisation (DESI) are its capability of direct analysis of solid surfaces without the need for sample preparation and the compatibility with portable mass spectrometers [68]. These advantages, in conjunction with the real time analysis capability of DESI-MS, its simplicity and the high throughput, give rise to a potential screening application of this technique.…”
Section: Desorption Electrospray Ionisationmentioning
confidence: 99%
See 2 more Smart Citations
“…Nitro-208 glycerin and nitrocellulose are both used in pharmaceutical prepara-209 tions [26,27]. Nitrocellulose also occurs in lacquers, varnishes and 210 celluloid films [26,27] and in printing [26].…”
mentioning