1989
DOI: 10.1016/s0022-1139(00)84149-4
|View full text |Cite
|
Sign up to set email alerts
|

Detailed investigation of fluoromethyl 1,1,1,3,3,3-hexafluoro-2-propyl ether (sevoflurane) and its degradation products. Part I: Synthesis of fluorinated, soda lime induced degradation products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

1994
1994
2013
2013

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(5 citation statements)
references
References 10 publications
0
4
0
1
Order By: Relevance
“…Gas chromatography combined with mass spectroscopy (Hewlett Packard 5890 with MSD 5971A) was used for identification of gas components and purity check of compound A (CH 2 F-O-C(ϭCF 2 ) (CF 3 )). Compound A was synthesized by one of the investigators (M. G. 9 ) and characterized by 1 H-NMR, 13 C-NMR, CH analysis and IR spectroscopy. Measurement of CH 3 OH and compound A was achieved by GC-FID detection using a Fisons 8000 equipped with a 50-µl heated (70°C) injection loop, a 2 m/0.53 mm id deactivated fused silica transfer line (Alltech, Munich, Germany), a Supel-Q Plot 30 m/0.53 mm id capillary column (Supelco, Bellafonte, USA) and a carrier pressure of 100 kPa (helium).…”
Section: Analysesmentioning
confidence: 99%
“…Gas chromatography combined with mass spectroscopy (Hewlett Packard 5890 with MSD 5971A) was used for identification of gas components and purity check of compound A (CH 2 F-O-C(ϭCF 2 ) (CF 3 )). Compound A was synthesized by one of the investigators (M. G. 9 ) and characterized by 1 H-NMR, 13 C-NMR, CH analysis and IR spectroscopy. Measurement of CH 3 OH and compound A was achieved by GC-FID detection using a Fisons 8000 equipped with a 50-µl heated (70°C) injection loop, a 2 m/0.53 mm id deactivated fused silica transfer line (Alltech, Munich, Germany), a Supel-Q Plot 30 m/0.53 mm id capillary column (Supelco, Bellafonte, USA) and a carrier pressure of 100 kPa (helium).…”
Section: Analysesmentioning
confidence: 99%
“…The refractive index at 30 °C was determined to n D ) 1.29. The racemic mixture of halodiether B was prepared according to a modified method 18 described by Huang et al 33 The refractive index at 30 °C was determined to n D ) 1.325. The polysiloxane PS255 (polydimethyl-(0.5-1%)-methylvinylsiloxane copolymer) was obtained from ABCR (Karlsruhe, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…The very high GC enantioseparation factors α for "compound B" on modified CDs have been found by mere chance as the target (Fig. 25, left) [130]. Since volatile anesthetics are recycled during anesthesia in re-breathing units, the exhaled carbon dioxide is trapped with soda lime.…”
Section: An Extraordinary Enantiomeric Differentiationmentioning
confidence: 96%