2009
DOI: 10.1016/j.ijms.2009.02.027
|View full text |Cite
|
Sign up to set email alerts
|

Detection of acetone and isoprene in human breath using a combination of thermal desorption and selected ion flow tube mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
39
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 53 publications
(40 citation statements)
references
References 22 publications
0
39
1
Order By: Relevance
“…Using standard samples the linearity of this system has been demonstrated within the concentration range from 1 to 10 ppb (Ross & Vermeulen, 2007). Hryniuk and Ross (2009) have now successfully used this ATD/SIFT-MS combination for breath analysis and found that there was a 1 to 1 concordance between the levels of isoprene and acetone in the breath of 12 healthy volunteers as measured using this combination technique and direct real-time SIFT-MS measurements.…”
Section: Recent Extensions To Sift-msmentioning
confidence: 87%
See 1 more Smart Citation
“…Using standard samples the linearity of this system has been demonstrated within the concentration range from 1 to 10 ppb (Ross & Vermeulen, 2007). Hryniuk and Ross (2009) have now successfully used this ATD/SIFT-MS combination for breath analysis and found that there was a 1 to 1 concordance between the levels of isoprene and acetone in the breath of 12 healthy volunteers as measured using this combination technique and direct real-time SIFT-MS measurements.…”
Section: Recent Extensions To Sift-msmentioning
confidence: 87%
“…The performance of Profile 3 SIFT-MS instruments has been illustrated by the data presented in several research papers produced by the teams at Keele , 2009Smith et al, 2008;Wang et al, 2008a;Wang, Š paněl, & Smith, 2008b;, at Prague (Španěl, Dryahina, & Smith, 2007a,b,c) and at Thunder Bay (Ross & Vermeulen, 2007;Ross, 2008;Hryniuk & Ross, 2009;Ross, Babay, & Ladouceur, 2009;). Scrutiny of these papers reveals the value and the quality of trace gas analyses obtained using current Profile 3 instruments.…”
Section: Performance Of the Profile 3 Instrumentmentioning
confidence: 99%
“…Breath analysis is a promising field for non-invasive diagnosis ( [208]; [183]) but the necessity for large screening studies to find markers for diseases and validate the results brings logistic challenges with: (1) the storage of breath samples for off-line analysis [193]; [209]) and (2) the standardization of the sampling method ( [210]; [34]). With a small scale test, the first point is addressed by looking at specific volatiles known to be present in elevated or decreased levels.…”
Section: Resultsmentioning
confidence: 99%
“…SIFT-MS emerged as a new technology for detection of exhaled breath gases in humans (Spanel et al, 2006;Pysanenko et al, 2008;Hryniuk and Ross, 2009). SIFT-MS can analyze complex mixtures regardless of the water vapor content in real time without sample preparation.…”
Section: 4selected Ion Flow Tube Mass Spectrometry (Sift-ms)mentioning
confidence: 99%
“…Figure 14 shows the schematic representation of the flowing after 25 glow-selected ion flow tube (FA-SIFT) instrument. Acetone, acetaldehyde, ammonia, ethanol and water vapor were measured by SIFT-MS at ppbv level in a single-breath exhalation in real time (Scotter et al, 2005;Hryniuk and Ross, 2009 downstream quadrupole and detected using a particle multiplier producing the resulting mass spectrum. Thus, quantification of particular trace gases in the air sample is achieved.…”
Section: 4selected Ion Flow Tube Mass Spectrometry (Sift-ms)mentioning
confidence: 99%