Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background Diffusion-weighted imaging (DWI) has become an important tool for the detection of cholesteatoma. The purpose of this study was to explore the value of 2D BLADE turbo gradient- and spin-echo imaging (TGSE BLADE) DWI in the quantitative diagnosis of recurrent temporal bone cholesteatoma (CS). Methods From March 2018 to October 2021, 67 patients with suspected recurrence of temporal bone CS after assessment by clinical otorhinolaryngologists who had undergone previous ear surgery for CS were prospectively evaluated by magnetic resonance imaging (MRI). Two radiologist assessed images independently. Quantitative parameters such as signal intensity ratio (SIR) calculated using, as a reference, the inferior temporal cortex (SIRT) and the background noise (SIRN), apparent diffusion coefficient (ADC) value, and ADC ratio (with pons as reference) measured on TGSE BLADE sequences were assessed. Using receiver operating characteristic (ROC) curve analysis, the optimal threshold and diagnostic performance for diagnosing recurrent CS were determined. Pair-wise comparison of the ROC curves was performed using the area under the ROC curve (AUC). Results Finally, 44 patients were included in this study, including 25 CS and 19 non-cholesteatoma (NCS). Mean SIRT and mean SIRN on TGSE BLADE DWI were significantly higher for CS than NCS lesions (p < 0.001). Meanwhile, mean ADC values and mean ADC ratios on ADC maps were significantly lower in the CS group than in the NCS group (p < 0.001). According to ROC analysis, the diagnostic efficacy of quantitative parameters such as SIRT (AUC = 0.967), SIRN (AUC = 0.979), ADC value (AUC = 1.0), and ADC ratio (AUC = 0.983) was significantly better than that of qualitative DWI (AUC = 0.867; p = 0.007, 0.009, 0.011 and 0.037, respectively). Conclusions Residual/recurrent temporal bone CS can be accurately detected using quantitative evaluation of TGSE BLADE DWI.
Background Diffusion-weighted imaging (DWI) has become an important tool for the detection of cholesteatoma. The purpose of this study was to explore the value of 2D BLADE turbo gradient- and spin-echo imaging (TGSE BLADE) DWI in the quantitative diagnosis of recurrent temporal bone cholesteatoma (CS). Methods From March 2018 to October 2021, 67 patients with suspected recurrence of temporal bone CS after assessment by clinical otorhinolaryngologists who had undergone previous ear surgery for CS were prospectively evaluated by magnetic resonance imaging (MRI). Two radiologist assessed images independently. Quantitative parameters such as signal intensity ratio (SIR) calculated using, as a reference, the inferior temporal cortex (SIRT) and the background noise (SIRN), apparent diffusion coefficient (ADC) value, and ADC ratio (with pons as reference) measured on TGSE BLADE sequences were assessed. Using receiver operating characteristic (ROC) curve analysis, the optimal threshold and diagnostic performance for diagnosing recurrent CS were determined. Pair-wise comparison of the ROC curves was performed using the area under the ROC curve (AUC). Results Finally, 44 patients were included in this study, including 25 CS and 19 non-cholesteatoma (NCS). Mean SIRT and mean SIRN on TGSE BLADE DWI were significantly higher for CS than NCS lesions (p < 0.001). Meanwhile, mean ADC values and mean ADC ratios on ADC maps were significantly lower in the CS group than in the NCS group (p < 0.001). According to ROC analysis, the diagnostic efficacy of quantitative parameters such as SIRT (AUC = 0.967), SIRN (AUC = 0.979), ADC value (AUC = 1.0), and ADC ratio (AUC = 0.983) was significantly better than that of qualitative DWI (AUC = 0.867; p = 0.007, 0.009, 0.011 and 0.037, respectively). Conclusions Residual/recurrent temporal bone CS can be accurately detected using quantitative evaluation of TGSE BLADE DWI.
Purpose: To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Materials and methods: Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale. The maximum size (Sizemax) of EOMs and corresponding ADCs (cADCs) of each patient were compared between the active and inactive phases. The clinical activity score (CAS) was used as a reference to assess the diagnostic performance of EOM ADCs for grading TAO activity. ROC analysis, Pearson correlation, and Wilcoxon signed-rank test were used for statistical analyses. Results: For scores of EOMs, the image quality of TGSE-BLADE-DWI was significantly higher than that of RESOLVE. There were no statistically significant differences between the AUCs of the two DWIs, Sizemax, or cADCs between the active and inactive phases. TGSE-BLADE-DWI ADCs were significantly higher than the RESOLVE ADCs in the right superior rectus, right lateral rectus, left superior rectus, and left inferior rectus. There were no statistically significant correlations between the cADC or Sizemax, and CAS. The highest AUC was 0.697 for RESOLVE and 0.657 for TGSE-BLADE-DWI. The best performing ADC threshold was 1.85 × 10−3 mm2/s with 85.7% sensitivity, 58.8% specificity and 66.67% accuracy for RESOLVE and 1.99 × 10−3 mm2/s with 79.0% sensitivity, and 55.6% specificity and 65.27% accuracy for TGSE-BLADE-DWI. Conclusion: Compared to RESOLVE, TGSE-BLADE-DWI provided improved image quality with fewer susceptibility artifacts and geometric distortions for EOM visualization and showed an equivalent performance in detecting active TAO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.