2018
DOI: 10.1007/s00330-017-5277-y
|View full text |Cite
|
Sign up to set email alerts
|

Detection of early cartilage damage: feasibility and potential of gagCEST imaging at 7T

Abstract: ObjectivesThe purpose was to implement a fast 3D glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) sequence at 7 T, test stability and reproducibility in cartilage in the knee in healthy volunteers, and evaluate clinical applicability in cartilage repair patients.MethodsExperiments were carried out on a 7-T scanner using a volume transmit coil and a 32-channel receiver wrap-around knee coil. The 3D gagCEST measurement had an acquisition time of 7 min. Signal stability and reproducibility of the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
40
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 43 publications
(44 citation statements)
references
References 31 publications
3
40
1
Order By: Relevance
“…GAG content can also be visualized by employing a gagCEST imaging protocol, as shown in earlier work . While the gagCEST signal can be contaminated by signals originating from other compounds or influenced by system imperfections, it can now be obtained in the same scan session as sodium; benefiting from both modalities.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…GAG content can also be visualized by employing a gagCEST imaging protocol, as shown in earlier work . While the gagCEST signal can be contaminated by signals originating from other compounds or influenced by system imperfections, it can now be obtained in the same scan session as sodium; benefiting from both modalities.…”
Section: Discussionmentioning
confidence: 99%
“…21 GAG content can also be visualized by employing a gagCEST imaging protocol, as shown in earlier work. 12 While the gagCEST signal can be contaminated by signals originating from other compounds or influenced by system imperfections, it can now be obtained in the same scan session as sodium; benefiting from both modalities. The sodium MRI will be more specific but is hindered by lower spatial resolution, and the higher resolution of gagCEST can reveal heterogeneities in more detail.…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation
“…We used MTR asym to evaluate the gagCEST effect. MTR asym is widely used, but other measures of the gagCEST effect also exist, as well as alternative methods for the correction of B 0 and B 1 inhomogeneity . It is possible that other methods may be beneficial in improving the sensitivity to CS‐C.…”
Section: Discussionmentioning
confidence: 99%
“…In this issue of European Radiology Brinkhof et al use gagCEST at 7T in volunteers and patients before cartilage repair surgery to show its clinical feasibility [10]. This study is also a first step to establish this technique as an imaging biomarker.…”
Section: What Does the Current Study Tell Us About Gagcest?mentioning
confidence: 98%