2006
DOI: 10.1016/j.jchromb.2006.02.044
|View full text |Cite
|
Sign up to set email alerts
|

Detection of hydroxyethylstarch (HES) in human urine by liquid chromatography–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
17
0

Year Published

2007
2007
2012
2012

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 8 publications
0
17
0
Order By: Relevance
“…As native urine samples were injected into the LC-MS/MS system, the robustness of the assay regarding column lifetime and system contamination was demonstrated with the analyses of approximately 500 samples without complications. For obligatory confirmation of suspicious screening results established methods are available that enable the unambiguous identification of HES and dextran (Deventer et al, 2006;Thevis et al, 2000b;Guddat et al 2005).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…As native urine samples were injected into the LC-MS/MS system, the robustness of the assay regarding column lifetime and system contamination was demonstrated with the analyses of approximately 500 samples without complications. For obligatory confirmation of suspicious screening results established methods are available that enable the unambiguous identification of HES and dextran (Deventer et al, 2006;Thevis et al, 2000b;Guddat et al 2005).…”
Section: Discussionmentioning
confidence: 99%
“…An aliquot of 90 μL of urine was transferred to a HPLC vial and 10 μg of the internal standard (IS) β-cyclodextrin (10 μL of a 1 mg/mL aqueous solution, 2006;Gutierrez-Gallego and Segura, 2004). However, the increasing quantity of samples and substances tested in doping control requires faster screening procedures, combining higher sample throughput with simplified sample preparation, reliability and robustness.…”
Section: Urine Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…90% of the dose is eliminated through the kidneys with an half-life of about 17 days [4]. Analytical procedures usually applied to the determination of HES in human urine are gas chromatography-mass spectrometry (GC-MS) [5] and liquid chromatography-mass spectrometry (LC-MS) [6][7][8]. These methods require time-consuming pretreatment steps, with an acid hydrolysis (30-60 min) to generate the 2,3 and 6-hydroxyethylglucose (fragments, used and accepted as proof of HES administration, with ␣ and ␤ isomers due to the anomeric centre at C1.…”
Section: Introductionmentioning
confidence: 99%
“…No simple methods are available for monitoring HES plasma levels; present technologies to measure HES are based on gas chromatography-mass spectrometry, which are time-consuming and need advanced equipment [3]. Here, we applied Lugol's iodine solution (LUGOL; Sigma-Aldrich, Steinheim, Germany) to determinate HES concentrations in plasma and compare the results with those obtained by high-performance liquid chromatography (HPLC).…”
mentioning
confidence: 99%