2016
DOI: 10.1007/s00216-016-9587-8
|View full text |Cite
|
Sign up to set email alerts
|

Detection of influenza virus by a biosensor based on the method combining electrochemiluminescence on binary SAMs modified Au electrode with an immunoliposome encapsulating Ru (II) complex

Abstract: Recently, point of care testing (POCT) used for diagnosis of influenza infection has a problem showing false negative diagnosis because of the low sensitivity. We would like to report detection of influenza virus A (H1N1) by an immunosensor based on electrochemiluminescence (ECL) that uses an immunoliposome encapsulating tris(2,2'-bipyridyl)ruthenium(II) complex. By using the sensor, we could detect the virus that competed with hemagglutinin (HA) peptide immobilized on self-assembled monolayers (SAMs) in immun… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 29 publications
0
21
0
Order By: Relevance
“…When antireflective chip condition was perturbed due to binding to, e.g., an antibody, the reflected light changes were quantitatively detected. Katayama et al [140] created an influenza virus biosensor based on two methods: electrochemiluminescence (ECL) of modified Au electrode combined with immunoliposome encapsulating Ru (II) complex. The authors have achieved sensitivity higher than ELISA; the detection range was from 2.7 × 10 2 to 2.7 × 10 3 PFU/mL.…”
Section: Novel Detection Methods Of Influenza Virusmentioning
confidence: 99%
“…When antireflective chip condition was perturbed due to binding to, e.g., an antibody, the reflected light changes were quantitatively detected. Katayama et al [140] created an influenza virus biosensor based on two methods: electrochemiluminescence (ECL) of modified Au electrode combined with immunoliposome encapsulating Ru (II) complex. The authors have achieved sensitivity higher than ELISA; the detection range was from 2.7 × 10 2 to 2.7 × 10 3 PFU/mL.…”
Section: Novel Detection Methods Of Influenza Virusmentioning
confidence: 99%
“…Variations of this loaded immunoliposome platform have since been applied to the detection of the influenza virus biomarker hemagglutinin. 151,152…”
Section: Metal-based Signal Generationmentioning
confidence: 99%
“…Viruses are intracellular parasites unlike other microorganisms. These agents have only a few number of responsible genes for the synthesis of new viruses and most of them used different enzymes which created by the host cell [1]. So, fast and well-timed diagnosis of these diseases is very important due to the limited treatment options.…”
Section: Introductionmentioning
confidence: 99%