Fourier transform infrared spectroscopy (FT-IR) was used to determine 20 different measurands in honey.The reference values for 144 honey samples of different botanical origin were determined by classical physical and chemical methods. Partial least squares regression was used to develop the calibration models for the measurands studied. They were validated using independent samples and proved satisfying accuracies for the determination of water (R 2 =0.99), glucose (0.94), fructose (0.84), sucrose (0.91), melezitose (0.98) and monosaccharide content (0.82) as well as fructose/glucose ratio (0.98), glucose/water ratio (0.94), electrical conductivity (0.98), pH-value (0.87) and free acidity (0.96). The prediction accuracy for hydroxymethylfurfural, proline and the minor sugars maltose, turanose, erlose, trehalose, isomaltose and kojibiose was rather poor. The results demonstrate that mid-infrared spectrometry is a valuable, rapid and non-destructive tool for the quantitative analysis of the most important measurands in honey.