2016
DOI: 10.1097/gox.0000000000000715
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Perforators Using Smartphone Thermal Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“… 15 In 2016, Hardwicke et al 16 described using a low-end, smartphone-compatible thermal camera, the FLIR ONE for pre-, intra-, and postoperative use, concluding that it provided a low-cost alternative that could identify hotspots for confirmation using HHD. Other authors have reported positive results with low-end thermal cameras, 17 21 and a study comparing the FLIR ONE with CTA for identification of arterial perforators reported high concordance between the methods. 22 …”
Section: Introductionmentioning
confidence: 91%
“… 15 In 2016, Hardwicke et al 16 described using a low-end, smartphone-compatible thermal camera, the FLIR ONE for pre-, intra-, and postoperative use, concluding that it provided a low-cost alternative that could identify hotspots for confirmation using HHD. Other authors have reported positive results with low-end thermal cameras, 17 21 and a study comparing the FLIR ONE with CTA for identification of arterial perforators reported high concordance between the methods. 22 …”
Section: Introductionmentioning
confidence: 91%
“…The FLIR C2 IR camera is a professional tool for performing a wide variety of temperature scans. In the medical field, some practitioners use this tool to scan the process of wound healing [10].…”
Section: Advances In Biological Sciences Research Volume 12mentioning
confidence: 99%
“…The technique for using the FLIROne Camera to venous perforators has already been defined. Suphachokauychai et al [ 4 ] have already provided guidelines for the use of these cameras to obtain accurate results. They noted that firstly the camera should be used on a dry surface.…”
Section: Ideamentioning
confidence: 99%
“…Ideally the measuring distance should be 100 cm and the thermal range should be locked at 25℃–30℃. These authors note that this technique has become their favored one for identifying vascular perforators, allowing them the freedom to design a free-style perforator flap [ 4 ]. We decided to follow these parameters for our measurements.…”
Section: Ideamentioning
confidence: 99%
See 1 more Smart Citation