Detection of Polymer Insulator Surface Based on the Effects of Tropical Climate Using Partial Discharge Signals Measurement

Abstract: One important component in the high voltage overhead lines placed on the transmission tower is the insulator. When polymer insulators are installed in tropical climates, there will be two conditions occurs, such as: i) the changes from wet to dry will cause the pollutant particles in the air will attach to the surface of the insulator. This condition will cause the sedimentation on the surface of the insulator; ii) the changes from dry to wet will form a conductive layer that leads to the leakage current flow.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…This case indicated that in addition to being caused by wetting intensity, the increasing rates were influenced positively by applied voltages. The rising insulator leakage currents due to rainfall were also implied in [42], [43], [44], and [45] as a low correlation of 0.31 [46] and reciprocal to the applied voltage [47].…”
Section: F Leakage Currents To Environmental Parameter Regressionsmentioning
confidence: 99%
“…This case indicated that in addition to being caused by wetting intensity, the increasing rates were influenced positively by applied voltages. The rising insulator leakage currents due to rainfall were also implied in [42], [43], [44], and [45] as a low correlation of 0.31 [46] and reciprocal to the applied voltage [47].…”
Section: F Leakage Currents To Environmental Parameter Regressionsmentioning
confidence: 99%
“…The insulator specification that is used in this research is based on the previous research [5]. The 20 kV AC supply voltage component as the voltage applied to the test object (insulator) is equipped with an input resistance (Rs) for the formation of an impulse voltage.…”
Section: Atlantis Highlights In Engineering Volumementioning
confidence: 99%
“…In this system, there are 4 ZMPT101B voltage sensors on each AC input and output voltage controller to Mirza Ghulam Ahmad 1*) , Moh. Zaenal Efendi 2) , and Rachma Prilian Eviningsih 3) Manuscript received 2023-07-24 ; revised 2023-08-08; accepted 2023-09-13…”
Section: Introductionmentioning
confidence: 99%