2002
DOI: 10.1021/la0262710
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Tl(I) Transport through a Gramicidin−Dioleoylphosphatidylcholine Monolayer Using the Substrate Generation−Tip Collection Mode of Scanning Electrochemical Microscopy

Abstract: We report the use of scanning electrochemical microscopy (SECM) to control the generation of Tl(I) at a mercury substrate and detect this species at a mercury-coated tip to study the transport of these ions through ion channels. The transport of Tl(I) across gramicidin D half-channels imbedded in a dioleoylphosphatidylcholine (DOPC) monolayer supported on a Tl amalgam hanging mercury drop electrode (HMDE) was studied using the substrate generation-tip collection mode of SECM. A Hg/Pt "submarine" electrode, use… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
1

Year Published

2007
2007
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(29 citation statements)
references
References 40 publications
0
28
0
1
Order By: Relevance
“…This method holds great promise for its potential application in situ by coating Hg on microelectrodes with capillary electrophoresis and dialysis techniques. Combined with other modern analytical techniques, [36][37][38] it might be anticipated to play a unique role in direct detecting free radicals generated in biooxidation of DA for the studies of the mechanism of AD relating to the Al toxicity. 29,39 ANALYTICAL SCIENCES NOVEMBER 2007, VOL.…”
Section: Discussionmentioning
confidence: 99%
“…This method holds great promise for its potential application in situ by coating Hg on microelectrodes with capillary electrophoresis and dialysis techniques. Combined with other modern analytical techniques, [36][37][38] it might be anticipated to play a unique role in direct detecting free radicals generated in biooxidation of DA for the studies of the mechanism of AD relating to the Al toxicity. 29,39 ANALYTICAL SCIENCES NOVEMBER 2007, VOL.…”
Section: Discussionmentioning
confidence: 99%
“…Heavy Metal Monitoring at Solid/Solution Interfaces measured at the tip and the distance from the source of the electroactive species [27,41], the subsequent current decrease as the microtip is moved further is, apparently, not consistent with the above view of the metal ion flux direction.…”
Section: Asv-secm Evaluation Of Spatial Ion Mobility and Time Evolutionmentioning
confidence: 99%
“…For more complex situations, solutions of the partial differential equations have been obtained [114,115].…”
Section: Theory Of the Generation-collection Modementioning
confidence: 99%