2004
DOI: 10.1016/j.radphyschem.2004.04.058
|View full text |Cite
|
Sign up to set email alerts
|

Detectors for medical radioisotope imaging: demands and perspectives

Abstract: Radioisotope imaging is used to obtain information on biochemical processes in living organisms, being a tool of increasing importance for medical diagnosis. The improvement and expansion of these techniques depend on the progress attained in several areas, such as radionuclide production, radiopharmaceuticals, radiation detectors and image reconstruction algorithms. This review paper will be concerned only with the detector technology.We will review in general terms the present status of medical radioisotope … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 43 publications
0
10
0
Order By: Relevance
“…In this way, by using the attenuation coefficient of the LYSO and the exponential attenuation law, the boundaries of the 4 depth of interaction intervals were obtained, the thickness of the intervals increase with depth in the crystal. Considering an attenuation length of the scintillator of 12 mm (Lopes et al 2004), the four DOIs corresponded to the intervals [0 mm, 1.83 mm], [1.83 mm, 3.99 mm], [3.99 mm, 6.62 mm] and [6.62 mm, 10 mm] (assuming a value of DOI = 0 mm at the entrance of the scintillator). Four Depth of Interaction intervals were chosen according to the results obtained in DOI resolution with the cMiCE detector in (Ling et al 2007).…”
Section: Methodsmentioning
confidence: 99%
“…In this way, by using the attenuation coefficient of the LYSO and the exponential attenuation law, the boundaries of the 4 depth of interaction intervals were obtained, the thickness of the intervals increase with depth in the crystal. Considering an attenuation length of the scintillator of 12 mm (Lopes et al 2004), the four DOIs corresponded to the intervals [0 mm, 1.83 mm], [1.83 mm, 3.99 mm], [3.99 mm, 6.62 mm] and [6.62 mm, 10 mm] (assuming a value of DOI = 0 mm at the entrance of the scintillator). Four Depth of Interaction intervals were chosen according to the results obtained in DOI resolution with the cMiCE detector in (Ling et al 2007).…”
Section: Methodsmentioning
confidence: 99%
“…[292735] Having a high intrinsic sensitivity reduces the detector thickness for obtaining suitable sensitivity and subsequently improves the spatial resolution. [27] Park et al .…”
Section: Cadmium Telluride Detectormentioning
confidence: 99%
“…Conventional SPECT system is mostly based on NaI(Tl) as main component of photon interaction, with a high luminous efficiency, and is costly effective. [ 1 5 9 ] However, it has some limitations such as low-energy resolution, low intrinsic spatial resolution, and hygroscopic. [ 5 10 11 ] The low intrinsic spatial resolution is confined by its low density (3.76 g/cm 3 )[ 10 12 13 14 ] and low-energy resolution related to the abundant PMTs needed for the positioning circuit.…”
Section: Introductionmentioning
confidence: 99%
“…The two primary diagnostic imaging methods are single photon imaging and positron emission tomography (PET) (29). The two primary diagnostic imaging methods are single photon imaging and positron emission tomography (PET) (29).…”
mentioning
confidence: 99%
“…Nuclear medicine (NM) uses radiotracers to diagnose and treat disease and in many countries is a subspecialty of radiology. The two primary diagnostic imaging methods are single photon imaging and positron emission tomography (PET) (29).…”
mentioning
confidence: 99%