1999
DOI: 10.1016/s0378-4347(99)00093-6
|View full text |Cite
|
Sign up to set email alerts
|

Determination of a new oral cephalosporin, S-1090, in human plasma and urine by direct injection high-performance liquid chromatography with ultraviolet detection and column switching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2000
2000
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…S-1090 presents peak plasma levels higher than those of cefdinir. After 100 mg dose, C max was 2.52 µg/ml in fasting subjects and 2.93 µg/ml in non-fasting volunteers [41]. In another study, single oral doses of 50, 75, 100 and 200 mg were administered to healthy human volunteers after a meal.…”
Section: Pharmacokineticsmentioning
confidence: 98%
“…S-1090 presents peak plasma levels higher than those of cefdinir. After 100 mg dose, C max was 2.52 µg/ml in fasting subjects and 2.93 µg/ml in non-fasting volunteers [41]. In another study, single oral doses of 50, 75, 100 and 200 mg were administered to healthy human volunteers after a meal.…”
Section: Pharmacokineticsmentioning
confidence: 98%
“…The concentration of the CPC residues in the compost was analyzed according to the following procedure [17,18]: 2 g of fresh sample was extracted by using a mixture of 15 ml acetonitrile, 10 ml acetonitrile saturated n-hexane and 5 g anhydrous sodium sulfate. After vortexing for 3 min and ultrasonic treatment for 15 min, the mixture was centrifuged at 6000 rpm for 5 min.…”
Section: Measurement Of Cpcmentioning
confidence: 99%
“…An internal-surface reversed-phase precolumn was applied for plasma assay, while two precolumn packed with cyano and phenyl bonded silica were effective for urine samples. 8 The analyte fraction transferred from the precolumn was finally separated on an octadecyl analytical column. Three precolumns with different bonded silica, connected in the order C 8 , silica-CN and silica-phenyl were included in a fully automated HPLC system for hydroxybenzeno[a]pyrene determination.…”
Section: On-line Coupling Of Spe With Hplcmentioning
confidence: 99%
“…Immunosorbents and molecular imprinted materials, which are based on molecular recognition, also allow achieving isolation and preconcentration in a single step. On-line SPE sample processing is very well suited for analysis of biological fluids such as urine [7][8][9][10]15,[20][21][22][23][25][26][27]30,31,37,39,[44][45][46]59,[94][95][96][97][98][99]102 and plasma. 7,8,15,16,18,20,22,33,36,37,56,57,69,[70][71][72][73]94,96,100 The determination of various pharmaceutics and drugs of this kind of matrices is required for pharmacokinetic and bioavailability studies 7,8,15,16, 30,38, 45,56, …”
Section: Application To Real Samplesmentioning
confidence: 99%