1997
DOI: 10.1007/s002160050325
|View full text |Cite
|
Sign up to set email alerts
|

Determination of acetaldehyde in liquid, solid and semi-solid food after pervaporation-derivatization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…In the literature, several methods were suggested for acetaldehyde analysis in foods, which include photometric, fluorimetric, chromatographic, and enzymatic methods. However, some of the methods are either expensive or lack sensitivity (enzymatic method), include time-consuming sample preparation steps or lack in specificity (spectrophotometric methods) [ 27 ]. The extraction of acetaldehyde with steam distillation is generally judged as being problematic, as considerable losses may occur (up to 30% in unpublished studies by the authors).…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, several methods were suggested for acetaldehyde analysis in foods, which include photometric, fluorimetric, chromatographic, and enzymatic methods. However, some of the methods are either expensive or lack sensitivity (enzymatic method), include time-consuming sample preparation steps or lack in specificity (spectrophotometric methods) [ 27 ]. The extraction of acetaldehyde with steam distillation is generally judged as being problematic, as considerable losses may occur (up to 30% in unpublished studies by the authors).…”
Section: Introductionmentioning
confidence: 99%
“…An FI-pervaporation approach has been reported for the determination of trimethylamine in fish samples, an important parameter in the evaluation of the freshness of fish [46]. The determination of acetaldehyde previously mentioned has also been applied on solid samples, such as grated bread, using pervaporation for the removal of this analyte from the matrix [45].…”
Section: Food Analysismentioning
confidence: 98%
“…This is the case of the FI-pervaporation manifold proposed for the continuous determination of acetaldehyde in fruit juice samples, satisfactorily applied to the determination of acetaldehyde in spiked fruit juice samples of different flavours [45].…”
Section: Food Analysismentioning
confidence: 99%
“…To date, the pervaporation phenomenon has rarely been applied in analytical chemistry. Some of the more recent applications have focused on different analytes: fluoride [20], acetaldehyde [21], trimethylamine [22], selenium [23], etc. Two previous papers for mercury speciation using the pervaporation approach were published by Bryce et al [24,25].…”
Section: Introductionmentioning
confidence: 99%