1999
DOI: 10.1039/a905415d
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Ag, Pb and Sn in aqua regia extracts from sediments by electrothermal atomic absorption spectrometry using Ru as a permanent modifier

Abstract: Ruthenium, deposited on a L'vov platform, is proposed as a permanent modi®er for the determination of Ag, Pb and Sn in aqua regia extracts from sediments by electrothermal atomic absorption spectrometry. The coating process is simple: a solution containing Ru is pipetted repeatedly on to the platform inserted in a graphite tube and is submitted to a temperature program. In a 50% v/v aqua regia solution, high pyrolysis temperatures could be used: 1200 ³C for Ag and Pb, and 1500 ³C for Sn. At these temperatures,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
73
1
4

Year Published

2001
2001
2006
2006

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 102 publications
(80 citation statements)
references
References 35 publications
2
73
1
4
Order By: Relevance
“…This temperature program also allowed the removal of contaminants from the modifiers, ensuring low blank values in the final analysis. 13 The mass of the metal deposited in the platform is quite high to assure a permanent coating, since a higher mass of the metal results in higher particle sizes and, therefore, smaller losses due to vaporization. 16 An increase in tube lifetime is also frequently observed, although no further investigation was performed in this work.…”
Section: Reagents and Samplesmentioning
confidence: 99%
See 4 more Smart Citations
“…This temperature program also allowed the removal of contaminants from the modifiers, ensuring low blank values in the final analysis. 13 The mass of the metal deposited in the platform is quite high to assure a permanent coating, since a higher mass of the metal results in higher particle sizes and, therefore, smaller losses due to vaporization. 16 An increase in tube lifetime is also frequently observed, although no further investigation was performed in this work.…”
Section: Reagents and Samplesmentioning
confidence: 99%
“…For the study of the modifiers, the following stock solutions were used: 10000 µg mL - 13 were carried out by pipetting 40 µL of a 500 µg mL -1 Ru solution or of a 500 µg mL -1 Ir solution into the graphite tube, on the platform, and submitting the tube to the temperature program shown in Table 2. The entire procedure, that is, pipetting and heating, was repeated 25 times, in order to obtain a mass of permanent modifier in the tube of 500 µg.…”
Section: Reagents and Samplesmentioning
confidence: 99%
See 3 more Smart Citations