2003
DOI: 10.1007/s00216-003-1838-9
|View full text |Cite
|
Sign up to set email alerts
|

Determination of antibiotics such as macrolides, ionophores and tiamulin in liquid manure by HPLC–MS/MS

Abstract: A method for the analysis of several macrolide and ionophore antibiotics as well as tiamulin in liquid manure was developed. Reversed-phase liquid chromatography and atmospheric pressure chemical ionisation (APCI) tandem mass spectrometry was used for detection.High-performance liquid chromatographic (HPLC) separation of the antibiotics was achieved in 35 min. The analytes were extracted with ethyl acetate and the extracts were cleaned up by solid-phase extraction on a diol SPE cartridge. Recovery experiments … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
45
0
5

Year Published

2006
2006
2019
2019

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 112 publications
(53 citation statements)
references
References 25 publications
3
45
0
5
Order By: Relevance
“…Some of them are conducted by gas chromatography, HPLC and HPLC-MS (Markus & Scherma, 1993a;Chen et al, 2006). The reported LOD of these methods ranged from 0.0014 ppm for HPLC-MS (Schlusener et al, 2003) and 10 ppm for HPLC (Markus & Scherma, 1993b). The sensitivity and the specificity by GC (Markus & Scherma, 1993c) and traditional HPLC is lower than those of LC-MS/MS analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Some of them are conducted by gas chromatography, HPLC and HPLC-MS (Markus & Scherma, 1993a;Chen et al, 2006). The reported LOD of these methods ranged from 0.0014 ppm for HPLC-MS (Schlusener et al, 2003) and 10 ppm for HPLC (Markus & Scherma, 1993b). The sensitivity and the specificity by GC (Markus & Scherma, 1993c) and traditional HPLC is lower than those of LC-MS/MS analysis.…”
Section: Discussionmentioning
confidence: 99%
“…68 Apesar da predominância do uso de ESI na análise de macrolídeos por LC-MS, a APCI tem sido usada em algumas aplicações e demonstrado vantagens com relação à redução do efeito matriz. [70][71][72] Especialmente quando se trata de fontes ESI, o efeito matriz deve ser considerado em análises quantitativas por LC-MS. Os componentes da matriz podem tanto melhorar como suprimir os sinais dos analitos, e seu efeito pode variar de amostra para amostra. O efeito matriz pode ser estimado comparando-se o sinal dos analitos em solvente com seu respectivo sinal na presença da matriz, através da adição de seus padrões analíticos no extrato, após todo o processo de tratamento de amostra.…”
Section: Ionizaçãounclassified
“…The presence of these compounds in the environment could potentially affect many aspects of ecosystem function including alteration of bacterial populations leading to nutrient cycle impacts, potential adverse effects to aquatic and non-target organisms, and possibly influence human health (10,11). One environmental entry point of antibiotics is through land application of manure (7,12,13). Antibiotics are administered to livestock and poultry for treatment of infections as well as for disease prevention, growth promotion, and feed efficiency (14,15).…”
Section: Introductionmentioning
confidence: 99%